4. Commissioning
4-34
Festo P.BE-SPC11-SYS-ASI-EN en 0203NH
You can move the mass into the saved end positions or
intermediate positions with the input bits P.01...P.04. When
an end position is reached, the moveable mass will be
pressed against the stop with a pressure equal at maximum
to the operating pressure. When an intermediate position is
reached, the moveable mass stands closed-loop controlled in
that position.
Input bit
Description
D0: P.01
I1
If the input bits P.02, P.03 and P.04 supply a 0-signal (0 V), the positioning order
to move to end position P.01 will be sent by a 1-signal at these input bits.
1)
D1: P.02
I2
If the input bits P.01, P.03 and P.04 supply a 0-signal (0 V), the positioning order
to move to end position P.02 will be sent by a 1-signal at these input bits.
1)
D2: P.03
I3
If the input bits P.01, P.03 and P.04 supply a 0-signal (0 V), the positioning order
to move to the taught intermediate position P.03 will be sent by a 1-signal at
these input bits.
1)
D3: P.04
I4
If the input bits P.01, P.02 and P.03 supply a 0-signal (0 V), the positioning order
to move to the taught intermediate position P.04 will be sent by a 1-signal at
these input bits.
1)
1) A change of direction is possible at any time. Positioning tasks must be clear. If 2, 3 or all 4 bits are
set, there will be no reaction.
Summary of Contents for Soft Stop SPC11 Series
Page 2: ......
Page 14: ...Contents and general instructions XII Festo P BE SPC11 SYS ASI EN en 0203NH ...
Page 15: ...Summary of components 1 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 1 ...
Page 25: ...Fitting 2 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 2 ...
Page 28: ...2 Fitting 2 4 Festo P BE SPC11 SYS ASI EN en 0203NH ...
Page 29: ...Installation 3 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 3 ...
Page 61: ...Commissioning 4 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 4 ...
Page 100: ...4 Commissioning 4 40 Festo P BE SPC11 SYS ASI EN en 0203NH ...
Page 101: ...Diagnosis and error treatment 5 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 5 ...
Page 114: ...5 Diagnosis and error treatment 5 14 Festo P BE SPC11 SYS ASI EN en 0203NH ...
Page 127: ...Technical appendix B 1 Festo P BE SPC11 SYS ASI EN en 0203NH Appendix B ...