5. Diagnosis and error treatment
5-5
Festo P.BE-SPC11-SYS-ASI-EN en 0203NH
Fault no.
Eliminating faults
Operating status
Amplification stage, cushioning stage or
system parameter set incorrectly.
S
Correct the parameters
The measuring system has no valid length
code (non-permitted measuring system
length or length code does not exist).
Servicing required
SPC11 damaged (EEPROM-ACK fault).
S
Replace the SPC11
Measuring system type is not supported
(invalid measuring system ID read).
S
Replace the measuring system
Communication to Temposonics is faulty
(non-plausible data has been received).
S
Check the measuring system
length or replace the measuring
system.
Communication to Temposonics is faulty
(non-plausible data has been received).
S
Check the measuring system
length or replace the measuring
system.
Incorrect direction of movement ascertained
during positioning stroke; tubing is incor-
rectly connected.
S
Correct the tubing of the propor-
tional directional control valve.
Time out, The position cannot be reached
fast enough (positioning timeout approx.
10 s).
S
Remove obstruction in positioning
path or check compressed air
supply.
Intermediate position does not exist or is
outside the permitted positioning range.
S
Increase the positioning range
and teach the end positions
again, in order that the intermedi-
ate positions lie within the per-
mitted positioning range.
or
S
Teach the intermediate positions
again.
Summary of Contents for Soft Stop SPC11 Series
Page 2: ......
Page 14: ...Contents and general instructions XII Festo P BE SPC11 SYS ASI EN en 0203NH ...
Page 15: ...Summary of components 1 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 1 ...
Page 25: ...Fitting 2 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 2 ...
Page 28: ...2 Fitting 2 4 Festo P BE SPC11 SYS ASI EN en 0203NH ...
Page 29: ...Installation 3 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 3 ...
Page 61: ...Commissioning 4 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 4 ...
Page 100: ...4 Commissioning 4 40 Festo P BE SPC11 SYS ASI EN en 0203NH ...
Page 101: ...Diagnosis and error treatment 5 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 5 ...
Page 114: ...5 Diagnosis and error treatment 5 14 Festo P BE SPC11 SYS ASI EN en 0203NH ...
Page 127: ...Technical appendix B 1 Festo P BE SPC11 SYS ASI EN en 0203NH Appendix B ...