4. Commissioning
4-12
Festo P.BE-SPC11-SYS-ASI-EN en 0203NH
The display shows the letter A (
A
mplification stage) and
the stage set (here 02).
(A.02)
If you have activated the modification mode by mistake, you
can abort the procedure by switching off the power supply. If
you have already carried out the teach procedure, you can
hereby avoid the need to carry out this procedure again.
With the b/- you can modify the parameter displayed
and transfer it with Enter (see section 4.2). When the last
parameter has been transferred, the SPC11 then indicates
readiness to carry out the teach procedure (t flashes).
Create status as at delivery
Prerequisites:
The measuring system must
not
be connected. The yellow
AS-Interface bus cable must
not
be connected, as otherwise
the button functions of the SPC11 cannot be used. The com-
pressed air supply must be switched off.
Use the buttons as follows to create the status as at delivery:
1. If necessary, switch off the compressed air and the power
supplies.
2. Disconnect the measuring system cable from the measur-
ing system.
3. Switch on the power supply.
The SPC11 will then show fault E01 (measuring system
not connected...).
(E.01)
Summary of Contents for Soft Stop SPC11 Series
Page 2: ......
Page 14: ...Contents and general instructions XII Festo P BE SPC11 SYS ASI EN en 0203NH ...
Page 15: ...Summary of components 1 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 1 ...
Page 25: ...Fitting 2 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 2 ...
Page 28: ...2 Fitting 2 4 Festo P BE SPC11 SYS ASI EN en 0203NH ...
Page 29: ...Installation 3 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 3 ...
Page 61: ...Commissioning 4 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 4 ...
Page 100: ...4 Commissioning 4 40 Festo P BE SPC11 SYS ASI EN en 0203NH ...
Page 101: ...Diagnosis and error treatment 5 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 5 ...
Page 114: ...5 Diagnosis and error treatment 5 14 Festo P BE SPC11 SYS ASI EN en 0203NH ...
Page 127: ...Technical appendix B 1 Festo P BE SPC11 SYS ASI EN en 0203NH Appendix B ...