4. Commissioning
4-8
Festo P.BE-SPC11-SYS-ASI-EN en 0203NH
4.2
Pre-parametrizing in the office
The permitted values of the parameters for the drive you are
using can be found in the appropriate axis-specific supple-
ment.
All the parameters are deleted at the factory (when supplied).
When the power supply is switched on, the SPC11 expects
the parameters to be entered. In preparation for commission-
ing, the parameters can be set without setting up the drive
“in the office.” This simplifies the commissioning of large
series in production.
Set the parameters without drive (in the office) as follows:
The values and stages specified here are only examples.
Enter instead of these the values and stages valid for your
drive structure (see drive-specific supplement).
1. Switch off the power supply for the AS-Interface bus or
disconnect the bus cable.
For commissioning via the keyboard the AS-Interface
cable (bus) must be disconnected or without power
applied.
2. Switch on the operating voltage for the SPC11.
The SPC11 will then show briefly the version number of
the internal firmware.
The SPC11 then expects the amplification stage to be
entered. The display shows the letter A (
A
mplification
stage). The figures indicate the stage (here 0).
(A.00)
3. Now set the desired amplification stage with the buttons
+/- (see axis-specific supplement), e.g. 02.
(A.02)
Summary of Contents for Soft Stop SPC11 Series
Page 2: ......
Page 14: ...Contents and general instructions XII Festo P BE SPC11 SYS ASI EN en 0203NH ...
Page 15: ...Summary of components 1 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 1 ...
Page 25: ...Fitting 2 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 2 ...
Page 28: ...2 Fitting 2 4 Festo P BE SPC11 SYS ASI EN en 0203NH ...
Page 29: ...Installation 3 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 3 ...
Page 61: ...Commissioning 4 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 4 ...
Page 100: ...4 Commissioning 4 40 Festo P BE SPC11 SYS ASI EN en 0203NH ...
Page 101: ...Diagnosis and error treatment 5 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 5 ...
Page 114: ...5 Diagnosis and error treatment 5 14 Festo P BE SPC11 SYS ASI EN en 0203NH ...
Page 127: ...Technical appendix B 1 Festo P BE SPC11 SYS ASI EN en 0203NH Appendix B ...