Commissioning
© Festo Didactic
8065842 en
59
Requirements
–
Cylinder for Z and X-axis has been attached.
–
Pneumatic port of the cylinder has been made.
–
Compressed air supply is switched on.
–
Electrical connection of the proximity switches has been made.
–
Power supply is available.
Procedure
1.
The cylinder is in the position to be queried.
2.
Move the proximity switch as far as the switching status display (LED) appears.
3.
Move the proximity switch into the same direction by a few millimeters as far as the switching status
display disappears.
4.
Move the proximity switch halfway between the switch on and the switch off position.
5.
Tighten the locking screw of the proximity switch with an Allen key SW1.3.
6.
Please check the position of the proximity switch by repeated test runs of the cylinder.