Commissioning
© Festo Didactic
8065842 en
47
Adjusting the CP application module and fixing it on the basic module CP Lab Conveyor
•
Use raised head screws M5x8, in order to connect the mounting brackets (1) of the CP application
module Measuring, at first loosely, with the cross profiles (2) of the basic module CP Lab Conveyor.
•
After setting all raised head screws, you can still move the CP application module to the position
required.
•
Push a carrier with pallet and front cover to the stopper position. The front cover points with its inside
upwards. The drilled hole of the front cover is on the left side.
•
Have a visual inspection to make sure that the two distance sensors are capable of registering the front
cover more or less in medium range.
•
Now tighten the raised head screws.
•
Then put the black covers onto the mounting brackets.
Tightening the CP application module / illustration similar
Position
Description
1
CP application module: mounting bracket with cover
2
basic module CP Lab Conveyor: cross profile
Summary of Contents for CP Factory