Edgebander with glue pot
G 200 / G 220
It is forbidden to connect the neutral to the earth.
The main power system must be provided with a neutral and an efficient earth line.
Intervention with the fuses or servo motors requires you to open the electrical box behind the control panel,
using a flat screwdriver. Maximum safety precautions must be taken before carrying out these operations. Pull
the main power supply plug out of the socket.
mains voltage according to specification plate
±10%
Safeguarding
see circuit plan
Power supply cord (H07RN-F)
3x2,5 mm²/ 5x2,5 mm²
Triggering characteristic
C
Attention! A wrong connection (for instance inverting a phase with the neutral or not connecting the neutral)
DAMAGES IRREPARABLY: heating elements, motors.
Technical data
4.4 Electrical connection
4.5 Particle emissions
Warning! Danger! Electric current!
All electrical repairs must be carried out by a qualified electrician.
The working areas of this machine comply to DGUV
Information 209-044 and are classed as dust reduced.
The maximum concentration level of 2 mg/m³ of inhala-
ble dust in the air will not be exceeded.
This only applies if the conditions that are specified in
the section >Extraction< are adhered to.
See chapter entitled >Setup and installation<