background image

 
 
 

MANUAL 

 

 

 

final 

– public (B) 

2018-09-18 

– H71011-0e-ID-B.docx

 

 

ID ISC.ANT.U500/270-DM 

(EU:

 

4923.000; FCC: 4922.000)

 

UHF DM (Direction Detection)  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for ID ISC.ANT.U500/270-DM

Page 1: ...MANUAL final public B 2018 09 18 H71011 0e ID B docx ID ISC ANT U500 270 DM EU 4923 000 FCC 4922 000 UHF DM Direction Detection...

Page 2: ...errors may not be completely avoided we are always grateful for your useful tips The instructions given in this manual are based on advantageous boundary conditions FEIG ELECTRONIC GmbH does not give...

Page 3: ...r issue If bits within one byte are filled with these bit spaces are reserved for future extensions or for internal testing and manufacturing functions These bit spaces must not be changed as this may...

Page 4: ...500 270 DM and Host 11 5 1 Configuration Commands and Control Commands 12 5 2 Buffered Read Mode 13 5 3 Notification Mode 14 6 Interface 15 6 1 Characteristics of TCP IP protocol 16 6 2 Serial Data Fo...

Page 5: ...ed 54 7 18 CFG40 LAN Settings Part 1 55 7 19 CFG41 LAN Settings Part 2 56 7 20 CFG47 Summer Winter Time 58 7 21 CFG49 Notification Channel 61 7 22 CFG63 Customer Parameter 63 8 Protocols for Reader Co...

Page 6: ...protocol frame 96 11 1 0x63 UPC Reset 96 11 2 0x66 Get UPC Info 97 11 3 0x6E UPC Diagnostic 101 11 4 0x72 Set UPC output 102 12 Protocols for Buffered Read Mode and Notification Mode 104 12 1 The Buf...

Page 7: ...alid for the device The manufacturer shall not be held legally responsible for inaccuracies errors or omissions in the manual or automatically set parameters for a device or for an incorrect applicati...

Page 8: ...UHF Reader Manual ID ISC ANT U500 270 DM FEIG ELECTRONIC GmbH Page 8 of 117 H71011 0e ID B docx 2 Revision History of Document Revision Date Page Description 0e 2017 10 20 Initial version...

Page 9: ...e FIFO First in First out frq Frequency FSK Frequency Shift Keying h Hour Hz Hertz ID Identification IDD Identifier Data IN Input LEN Length LOC Location LSB Least Significant Byte min Minutes ms Mill...

Page 10: ...NT U500 270 DM has some new features which are not supported by the cur rent ID ISC LRU1002 on the other hand the ISC ANT U500 270 DM does not support all features of the ID ISC LRU1002 Therefore the...

Page 11: ...The Buffered Read Mode and Notification Mode are used for the data exchange between Tran sponder and host whereas the Configuration Commands and the Reader Control Commands serves for adapting the Rea...

Page 12: ...ameters will be stored in the Reader memory To store the current configuration during a power down of the Reader the Reader Configuration has to be stored in the EEPROM After power up the Reader reads...

Page 13: ...ith the 12 4 0x22 Read Buffer command This command always reads the first available data sets from the data buffer However data already read have to be deleted with the 12 6 0x32 Clear Data Buffer com...

Page 14: ...lly not acknowledged by the host Thus the deletion of the transferred data with the 12 6 0x32 Clear Data Buffer com mand is not necessary As an option the acknowledgement can be enabled to synchronize...

Page 15: ...f 117 H71011 0e ID B docx 6 Interface The ID ISC ANT U500 270 DM has 2 interface ports The protocol frame of these ports can be different On the whole protocol frame is described in 6 2 Serial Data Fo...

Page 16: ...der side uses the keepalive option for detecting interrupted connec tions The default parameters for keepalive are initialized as listed in the table Parameter Value Note idle time 5 seconds The reade...

Page 17: ...ers or read from Transponders The communication between Reader and connected host terminal PC etc is executed by means of fixed protocols The used protocol is intended for data bus use and is equipped...

Page 18: ...3 4 5 6 7 n 2 STX 0x02 MSB ALENGTH LSB ALENGTH COM ADR CONTROL BYTE STATUS 1 DATA n 1 n LSB CRC16 MSB CRC16 NOTE The Reader supports the advanced protocol frame only STX The STX sign 0x02 defines tha...

Page 19: ...ssage or protocol data from or to the Reader DATA Is an optional data field with variable length The number of DATA bytes depends on the command The data will be sent always as MSB first if the Reader...

Page 20: ...B docx 6 3 CRC16 Calculation Algorithm Polynomial x16 x12 x5 1 CRC_POLYNOM 0x8408 Start Value 0xFFFF CRC_PRESET 0xFFFF C Example unsigned int crc CRC_PRESET for i 0 i cnt i cnt number of protocol byte...

Page 21: ...iguration block RAM EEPROM MODE specifies one or all configuration blocks Bit 7 6 5 4 3 2 1 0 Function LOC MODE CFGn address of configuration block The EEPROM configuration blocks are protected by a 1...

Page 22: ...ing this configuration block to RAM marked with 00 these bits or bytes are reserved for future extensions or for internal testing and manufacturing functions These bits or bytes and also any not descr...

Page 23: ...9 10 11 12 13 Contents 0x00 CFG_ACCESS 0x00 0x00 Default 0x00000000 READER ID AccessProtection Password Defines the password with which the host logs into the Reader for a read write access to the co...

Page 24: ...mands 8 4 0x81 Write Configuration and 8 5 0x83 Reset Configuration don t change the CFG0 register if all configuration blocks are used Also access protected Con figuration Pages will not be influence...

Page 25: ...0x00 0x00 0x01 Default Byte 7 8 9 10 11 12 13 Contents 0x2C 0x00 0x00 0x00 0x00 INTERFACE READER MODE Default 0x94 0x80 INTERFACES HostInterface Interfaces Flags for enabling the communication ports B...

Page 26: ...ffered Read Mode can be enabled b0 not used b1 BRM Mode NTF E By setting of this bit the Notification Mode can be enabled b0 Off b1 On only together with BRM Mode The following table lists the bit com...

Page 27: ...N ACTIVE 0x00 0x00 Default 0x2000 0x0000 0x00 Byte 7 8 9 10 11 12 13 Contents 0x00 0x00 0x00 0x00 0x00 0x00 OUT2 Time Default 0x00 IDLE MODE DigitalIO Output NoX IdleMode x 2 Defines the status of the...

Page 28: ...act b0 closed contact activates input b1 open contact activates input OUT2 TIME DigitalIO Output No2 SettlingTime Defines the holding time of the digital output OUT2 If the Reader receives a valid Tra...

Page 29: ...r drivers and Reader settings Byte 0 1 2 3 4 5 6 Contents 0x0010 RF POWER ANT REG 0x00 0x00 0x00 Default 0x17 0 8W 0x06 0x04 Byte 7 8 9 10 11 12 13 Contents 0x00 FREQ_US 0x00 NR_PREFER RED_CHN PREFERR...

Page 30: ...L RF POWER Watt RF POWER dBm 0x10 0 1 20 0 0x11 0 2 23 0 0x12 0 3 24 8 0x13 0 4 26 0 0x14 0 5 27 0 0x15 0 6 27 8 0x16 0 7 28 5 0x17 0 8 29 0 0x18 0 9 29 5 0x19 1 0 30 0 NOTE The maximal output power f...

Page 31: ...ead ers following regions are applicable REG Name Countries Number of Channels Frequency Band 0X06 Europe Armenia 4 865 MHz 868 MHz Austria Azerbaijan Belarus Belgium Bosnia Herzegovina Bulgaria Croat...

Page 32: ...n Pakistan Saudi Arabia United Arab Emirates New Zealand 0x26 Russia Russia 3 866 MHz 868 MHz 0x36 Africa Nigeria 4 865 MHz 868 MHz South Africa Tunisia 0x46 India India 3 865 MHz 867 MHz 0x56 Morocco...

Page 33: ...na China 16 920 5 MHz 924 5 MHz 0x24 Australia New Zealand Australia 9 921 5 MHz 926 MHz New Zealand 0x34 Brazil Brazil 10 25 902 MHz 907 5 MHz 915 MHz 927 5 MHz Peru 0x44 Israel Israel 3 915 MHz 916...

Page 34: ...el Frequency which is used by the FCC Reader as upper and lower limit NOTE These settings are only applicable for FCC Readers These settings are only applicable if Region 0xFF Unknown FCC is selected...

Page 35: ...302208_4_ChannelPlan PreferredChannels ChannelNoX x 1 4 Defines the preferred channels used by the European Reader NOTE These settings are only applicable for EU Readers These settings are only applic...

Page 36: ...UHF Reader Manual ID ISC ANT U500 270 DM FEIG ELECTRONIC GmbH Page 36 of 117 H71011 0e ID B docx 7 5 CFG4 5 Not used This configuration is not used supported by ID ISC ANT U500 270 DM...

Page 37: ...ge 37 of 117 H71011 0e ID B docx 7 6 CFG6 7 Reserved The configuration blocks CFG6 to CFG8 are reserved for future use Byte 0 1 2 3 4 5 6 Contents 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Default Byte 7 8 9...

Page 38: ...ed reserved MISC SENSITIVITY Default 00 00 00 00 00 00 00 MISC Special settings Bit 7 6 5 4 3 2 1 0 Function reserved CREATE BLACKLIST CREATE BLACKLIST OperatingMode BufferedReadMode Miscellaneous Bla...

Page 39: ...0x00 0x00 ACTION Default 0x00 TRIGGER MODE defines the mode of the scanner Bit 7 6 5 4 3 2 1 0 Function Trigger 0 Condi tion 0 0 0 0 Unlimited Valid Time Trigger OperatingMode BufferedReadMode Trigger...

Page 40: ...ode Trigger Enable_UnlimitTransponderValidTime OperatingMode NotificationMode Trigger Enable_UnlimitTransponderValidTime b0 Valid Time is limited to one Trigger Period The Valid Time s CFG12 is restar...

Page 41: ...the Trigger Condition and the Hold Time ACTION defines actions in trigger mode Bit 7 6 5 4 3 2 1 0 Function 0 0 0 0 NO_READ_ SIGNALIZATION RF OFF_AFTER _READ RF OFF_AFTER_READ OperatingMode BufferedRe...

Page 42: ...fault 0x0001 TR DATA 1 Selects the data types for read operation Bit 7 6 5 4 3 2 1 0 Function Exten sion DATE TIMER Byte Order DB DB SNR SNR OperatingMode BufferedReadMode DataSelector UID OperatingMo...

Page 43: ...Source ByteOrderOfData b0 MSB first b1 LSB first TIMER OperatingMode BufferedReadMode DataSelector Time OperatingMode NotificationMode DataSelector Time b0 no internal system timer b1 internal system...

Page 44: ...he data types for read operation Bit 7 6 5 4 3 2 1 0 Function DIREC TION MAC IN DIRECTION OperatingMode BufferedReadMode DataSelector Dxxxx OperatingMode NotificationMode DataSelector Dxxxx b0 no Dire...

Page 45: ...s read b00 Reader reads out the memory blocks according to the settings in DB ADR DB N D Start and D LGT b01 Reader reads out all blocks of the selected memory bank starting at DB ADR NOTE This functi...

Page 46: ...DataSource FirstDataBlock OperatingMode NotificationMode DataSource FirstDataBlock Address of first data block Range 0x00 0xFF DB N 5 OperatingMode BufferedReadMode DataSource NoOfDataBlocks Operating...

Page 47: ...UHF Reader Manual ID ISC ANT U500 270 DM FEIG ELECTRONIC GmbH Page 47 of 117 H71011 0e ID B docx 7 10 CFG12 13 Not used This configuration is not used supported by ID ISC ANT U500 270 DM...

Page 48: ...H Page 48 of 117 H71011 0e ID B docx 7 11 CFG14 Reserved The configuration block CFG14 is reserved for future use Byte 0 1 2 3 4 5 6 Contents 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Default Byte 7 8 9 10 1...

Page 49: ...UHF Reader Manual ID ISC ANT U500 270 DM FEIG ELECTRONIC GmbH Page 49 of 117 H71011 0e ID B docx 7 12 CFG15 16 Not used This configuration is not used supported by ID ISC ANT U500 270 DM...

Page 50: ...ge 50 of 117 H71011 0e ID B docx 7 13 CFG17 20 Reserved The configuration blocks CFG17 20 are reserved for future use Byte 0 1 2 3 4 5 6 Contents 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Default Byte 7 8 9...

Page 51: ...ge 51 of 117 H71011 0e ID B docx 7 14 CFG21 27 Reserved The configuration blocks CFG21 27 are reserved for future use Byte 0 1 2 3 4 5 6 Contents 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Default Byte 7 8 9...

Page 52: ...ge 52 of 117 H71011 0e ID B docx 7 15 CFG28 32 Reserved The configuration blocks CFG28 32 are reserved for future use Byte 0 1 2 3 4 5 6 Contents 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Default Byte 7 8 9...

Page 53: ...te 7 8 9 10 11 12 13 Contents LAN HOSTNAME Default 0x000000000000 CFG 34 Byte 0 1 2 3 4 5 6 Contents LAN HOSTNAME Default 0x00000000000000 Byte 7 8 9 10 11 12 13 Contents LAN HOSTNAME Default 0x000000...

Page 54: ...ge 54 of 117 H71011 0e ID B docx 7 17 CFG35 39 Reserved The configuration blocks CFG35 39 are reserved for future use Byte 0 1 2 3 4 5 6 Contents 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Default Byte 7 8 9...

Page 55: ...ORT_NUMBER_LAN 0x00 0x00 0x00 0x00 Default 0x27 0x11 10001 IP_ADDRESS_LAN HostInterface LAN IPv4 IPAddress Defines the IP address for wired LAN connection Changing of this parameter only be comes effe...

Page 56: ...ffective after writing saving this configuration block to EEPROM and a 0x64 Sys tem Reset of the RFC GW_ADDRESS_LAN HostInterface LAN IPv4 GatewayAddress Defines the gateway address for TCP IP connect...

Page 57: ...aximum number of retransmissions This is the number of times that the reader re transmits a keepalive packet to the host to check for connectivity The valid range is 1 255 KEEP INTERVAL HostInterface...

Page 58: ...n WDAY Together with SDAY_x defines the day of the week or date when the respective change should occur Bit 7 6 5 4 3 2 1 0 Function WDAY_END 0 7 WDAY_BGN 0 7 WDAY_BGN 0 Changeover date is defined by...

Page 59: ...by WDAY which lies between the days SDAY_x and SDAY_x 6 Example To have the changeover occur on the last Sunday of a month having 31 days set WDAY 1 Sunday and SDAY_x 25 31 6 The changeover then takes...

Page 60: ...ence by which the clock time deviates from winter to summer time Bit 7 6 5 4 3 2 1 0 Function SIGN MIN_INC SIGN Specifies the sign for the minute increments 1 0 MIN_INC 0 127 Defines the number of min...

Page 61: ...the notification channel Bit 7 6 5 4 3 2 1 0 Function ACK 0 0 0 0 0 0 0 ACK Acknowledge Notification OperatingMode NotificationMode Transmission Enable_Acknowledge b0 Notification must not be acknowle...

Page 62: ...ificationMode Transmission Destination IPv4 IPAddress Defines the destination IP address DEST IP PORT NUMBER OperatingMode NotificationMode Transmission Destination PortNumber Defines the destination...

Page 63: ...63 of 117 H71011 0e ID B docx 7 22 CFG63 Customer Parameter The configuration block CFG63 is used for customer parameter Byte 0 1 2 3 4 5 6 Contents 0x00 0x00 0x00 0x00 0x00 0x00 0x00 Default Byte 7 8...

Page 64: ...00 270 DM FEIG ELECTRONIC GmbH Page 64 of 117 H71011 0e ID B docx 8 Protocols for Reader Configuration Via the protocols for Reader configuration the Reader can be adapted to individual conditions of...

Page 65: ...MSB ALENGTH LSB ALENGTH COM ADR 0x87 DATE TIMER CRC16 Host Reader Byte 1 2 3 4 5 6 7 8 Contents STX 0x02 MSB ALENGTH LSB ALENGTH COM ADR 0x87 STATUS 6 CRC16 DATE Byte 6 7 TIME century year 0 99 0 99 8...

Page 66: ...the date Host Reader Byte 1 2 3 4 5 6 7 Contents STX 0x02 MSB ALENGTH LSB ALENGTH COM ADR 0x88 CRC16 Host Reader Byte 1 2 3 4 5 6 7 11 Contents STX 0x02 MSB ALENGTH LSB ALENGTH COM ADR 0x88 STATUS 7 D...

Page 67: ...ntents STX 0x02 MSB ALENGTH LSB ALENGTH COM ADR 0x80 CFG ADR CRC16 Host Reader Byte 1 2 3 4 5 6 7 20 19 20 Contents STX 0x02 MSB ALENGTH LSB ALENGTH COM ADR 0x80 STATUS CFG REC CRC16 CFG ADR Bit 7 6 5...

Page 68: ...Reader Byte 1 2 3 4 5 6 7 20 19 20 Contents STX 0x02 MSB ALENGTH LSB ALENGTH COM ADR 0x81 CFG ADR CFG REC CRC16 Host Reader Byte 1 2 3 4 5 6 7 8 Contents STX 0x02 MSB ALENGTH LSB ALENGTH COM ADR 0x81...

Page 69: ...16 Host Reader Byte 1 2 3 4 5 6 7 8 Contents STX 0x02 MSB ALENGTH LSB ALENGTH COM ADR 0x83 STATUS CRC16 CFG ADR Bit 7 6 5 4 3 2 1 0 Function LOC MODE CFGn Address of Configuration Block CFGn memory ad...

Page 70: ...ost Reader Byte 1 2 3 4 5 6 7 Contents STX 0x02 MSB ALENGTH LSB ALENGTH COM ADR 0x63 CRC16 Host Reader Byte 1 2 3 4 5 6 7 8 Contents STX 0x02 MSB ALENGTH LSB ALENGTH COM ADR 0x63 STATUS 8 CRC16 NOTE T...

Page 71: ...NGTH LSB ALENGTH COM ADR 0x64 Mode CRC16 Host Reader Byte 1 2 3 4 5 6 7 8 Contents STX 0x02 MSB ALENGTH LSB ALENGTH COM ADR 0x64 STATUS 9 CRC16 MODE Defines Controller which will be reset MODE Control...

Page 72: ...ter MODE different information can be requested from the Reader 0x00 RF Controller Firmware 0x03 RF Decoder Firmware 0x04 Firmware Identifier 0x05 Bootloader Firmware 0x10 Hardware Information 0x15 RF...

Page 73: ...on status of the development Firmware D REV is set to 0 in customized Firmware revisions HW TYPE Displays information about the Hardware Version SW TYPE Type of RFC Reader Firmware 0x83 ID ISC ANT U50...

Page 74: ...ware Information Host Reader Byte 1 2 3 4 5 6 7 8 9 10 Contents STX 0x02 MSB ALENGTH LSB ALENGTH COM ADR 0x66 STATUS 11 HW INFO D_HW 11 12 13 14 15 16 17 18 19 A_HW FREQUENCY PORT_TYPE Reserved Reserv...

Page 75: ...1 FCC frequencies supported UHF b0 UHF not supported b1 UHF supported HF b0 HF not supported b1 HF supported PORT_TYPE Flags for supported communication ports Bit 7 6 5 4 3 2 1 0 Function DISC BT USB...

Page 76: ...n configuration pages PERMISSION Byte 7 Bit 7 6 5 4 3 2 1 0 CFG_NO 0 1 2 3 4 5 6 7 Byte 8 Bit 7 6 5 4 3 2 1 0 CFG_NO 8 9 10 11 12 13 14 15 Byte 9 Bit 7 6 5 4 3 2 1 0 CFG_NO 16 17 18 19 20 21 22 23 Byt...

Page 77: ...TH COM ADR 0x66 STATUS 13 FLAGS DATA CRC16 FLAGS indicates additional settings Byte 5 Bit 7 6 5 4 3 2 1 0 0 0 DHCP v4 0 Disa bled v4 0 Sup ported v4 0 Supported v4 b0 not supported b1 supported Disabl...

Page 78: ...TS NR_OF_ OUTPUTS 9 10 11 NR_OF_ RELAYS CRC16 NR_OF_INPUTS Indicates the number of available Inputs NR_OF_OUTPUTS Indicates the number of available Outputs NR_OF_RELAYS Indicates the number of availab...

Page 79: ...UHF Reader Manual ID ISC ANT U500 270 DM FEIG ELECTRONIC GmbH Page 79 of 117 H71011 0e ID B docx Type Indicates the type of the devices BUS Adr Indicates the bus address of the device...

Page 80: ...DEV_ID Custom_L 15 16 17 18 19 20 21 22 23 24 FW_L TR_DRV_L FNC_L CRC16 DEV_ID Individual device identifier of the Reader CUSTOM_L Indicates which customer Firmware is licensed on the Reader FW_L Indi...

Page 81: ...3 4 5 6 7 Contents STX 0x02 MSB ALENGTH LSB ALENGTH COM ADR 0x66 STATUS 16 DATASETS 8 9 38 n 1 n MODE DATA CRC16 Repeated DATASETS times MODE Mode byte DATA Mode 0xFF Data record according to the defi...

Page 82: ...16 Host Reader Byte 1 2 3 4 5 6 7 8 Contents STX 0x02 MSB ALENGTH LSB ALENGTH COM ADR 0x6A STATUS 17 CRC16 RF OUTPUT Set the antenna outputs Bit 7 6 5 4 3 2 1 0 Function 0 0 0 0 0 Antenna Output Anten...

Page 83: ...TH LSB ALENGTH COM ADR 0x6E MODE CRC16 Host Reader Byte 1 2 3 4 5 6 7 n 2 n 1 n Contents STX 0x02 MSB ALENGTH LSB ALENGTH COM ADR 0x6E STATUS 18 DATA CRC16 MODE Reader Diagnostic Modes 0x01 Listing of...

Page 84: ...ns Flag A and B Error Set condition Clear condition Trouble shouting RF Power LED 5 NOISE The noise in the receiver channel is very high Select other preferred channel s or add more preferred chan nel...

Page 85: ...F Bit 7 6 5 4 3 2 1 0 Function ADC RTC UPC RF Decoder EE DEV1 EE_DEV1 Error during the communication with EEPROM Dev 1 RF Decoder Error during the communication with RF Decoder UPC Error during the co...

Page 86: ...ts in one protocol Host Reader Byte 1 2 3 4 5 6 7 Contents STX 0x02 MSB ALENGTH LSB ALENGTH COM ADR 0x6E STATUS 19 DATASET S 8 9 38 n 1 n MODE DATA CRC16 Repeated DATASETS times MODE Mode byte DATA Mo...

Page 87: ...itched on or off for the indicated period of time If the Reader receives a command Set Output all times that have been active until then are being overwritten by the new times included in the protocol...

Page 88: ...it configuration is reserved OUT S OUT S Output State defines the status of the output during the time defined in OUT TIME and provides the possibility to allocate its own flashing frequency to each o...

Page 89: ...or unlimited An exception is the time value 0 and 65535 0xFFFF see following table 0x0001 1 x 100ms 100ms 0xFFFE 65534 x 100ms 1 49 13 h 0xFFFF continuously active NOTE In order to reset a continuous...

Page 90: ...Byte 1 2 3 4 5 6 7 Contents STX 0x02 MSB ALENGTH LSB ALENGTH COM ADR 0x74 CRC16 Host Reader Byte 1 2 3 4 5 6 7 8 9 Contents STX 0x02 MSB ALENGTH LSB ALENGTH COM ADR 0x74 STATUS 21 INPUTS CRC16 INPUTS...

Page 91: ...ing the command it is no longer possible to change the region Host Reader Byte 1 2 3 4 5 6 7 Contents STX 0x02 MSB ALENGTH LSB ALENGTH COM ADR 0x8D CRC16 Host Reader Byte 1 2 3 4 5 6 7 8 Contents STX...

Page 92: ...TX 0x02 MSB ALENGTH LSB ALENGTH COM ADR 0xA0 READER ID CRC16 Host Reader Byte 1 2 3 4 5 6 7 8 Contents STX 0x02 MSB ALENGTH LSB ALENGTH COM ADR 0xA0 STATUS 23 CRC16 READER ID The READER ID is a passwo...

Page 93: ...The Reader configuration protocols allow the Reader to be adapted to the conditions found in indi vidual applications For this system the Peripheral Device is the UPC The UPC contains the LEDs Note To...

Page 94: ...bedded with this Pig gyback Command If the communication with the peripheral device fails the command returns with status 0x20 Fig 1 Communication of a system consisting of a Host Reader and UPC Peopl...

Page 95: ...of 117 H71011 0e ID B docx DEVICE The DEVICE defines the peripheral device DEVICE Value UPC 15 PORT The PORT defines the internal communication port PORT Value RS232 0x01 EMB REQ PRT EMB RSP PRT Embed...

Page 96: ...ocol frame 11 1 0x63 UPC Reset This protocol allows to reset the CPU Controller of the UPC The counter values of the people counter remain unchanged Host UPC Byte 1 2 3 4 5 7 8 Contents STX 0x02 MSB A...

Page 97: ...e Information 0xFF All MODE 0x00 RFC Controller Firmware Host UPC Byte 1 2 3 4 5 6 7 8 9 Contents STX 0x02 MSB ALENGTH LSB ALENGTH COM ADR 0x66 STATUS SW REV D REV 10 11 12 13 14 15 16 17 18 19 HW TYP...

Page 98: ...C ANT UPC 15 RX BUF RX BUF is the maximum receive buffer size of the Reader If a protocol from the host exceeds the RX BUF size the Reader responds with 0x81 PROTOCOL LENGTH ERROR TX BUF TX BUF is the...

Page 99: ...eserved Reserved Reserved CRC16 HW INFO internal use D HW byte 9 internal use byte 10 People Counter support b0 supported b1 Not supported The people counter is not supported by DM A HW internal use P...

Page 100: ...UHF Reader Manual ID ISC ANT U500 270 DM FEIG ELECTRONIC GmbH Page 100 of 117 H71011 0e ID B docx BT b0 not supported b1 supported DISC b0 Discovery not supported b1 Discovery supported...

Page 101: ...H COM ADR 0x6E MODE CRC16 Host UPC Byte 1 2 3 4 5 6 7 n 2 n 1 n Contents STX 0x02 MSB ALENGTH LSB ALENGTH COM ADR 0x6E STATUS DATA CRC16 MODE Reader Diagnostic Modes 0x04 Listing of detail information...

Page 102: ...mmand Set UPC Out put all times that have been active until then are being overwritten by the new times included in the protocol if they are 0 Host UPC 1 2 3 4 5 6 7 0x02 n UPC_ADR 0x72 Mode OUT N 8 9...

Page 103: ...OUT TIME active b10 OFF output for OUT TIME inactive b11 FLASH output for OUT TIME with OSF alternating OUTx frq b11 1 Hz b10 2 Hz b01 4 Hz b00 8 Hz OUT TIME By the values defined by OUT TIME the outp...

Page 104: ...ommands are necessary to read out sampled Transponder data sets The figure below illustrates the Buffered Read Mode procedure Host Reader 0x22 Read Buffer Command to the Reader to read data typ 6 ms H...

Page 105: ...ntinuously or a very short cycle time in time triggered mode is defined To prevent a notification overflow in a host application the acknowledgement option can be set In this case the notification mus...

Page 106: ...0e ID B docx 12 3 Transponder Access in the Buffered Read Mode and Notification Mode The Buffered Read Mode only reads data blocks from the Transponders in the antenna field After power up or a 9 1 0x...

Page 107: ...n 2 n 1 n DATA SETS DATA CRC16 DATA SETS Number of data sets to be transferred from the data buffer If the data buffer does not con tain the requested number of data sets the Reader responds with all...

Page 108: ...e ID B docx TR DATA2 Selects the data types for read operation Bit 7 6 5 4 3 2 1 0 Function DIRECTI ON MAC IN IN Input states MAC b0 no MAC address will be transmitted b1 MAC address will be transmitt...

Page 109: ...Data Type DATA Record Length byte no 1 2 MSB RecLen LSB RecLen Serial Number byte no 1 2 3 4 4 IDD LEN TR TYP IDDIB IDD LEN IDD data blocks byte no 1 2 3 4 4 DB N DB SIZE DB N DB SIZE DB Time byte no...

Page 110: ...ck size DB Data TIME Byte 1 2 3 4 TIME h min ms 0 23 0 59 0 59999 DATE Byte 1 2 TIME century year 0 99 0 99 3 4 5 month day time zone 1 12 1 31 0 23 IN Input number Bit 7 6 5 4 3 2 1 0 Function IN2 IN...

Page 111: ...right to left viewing direction to DM MAC ADR MAC address of the reader NOTE This command reads the same data sets until they are cleared with the 12 6 0x32 Clear Data Buffer command This command is o...

Page 112: ...ADR 0x31 CRC16 Host Reader Byte 1 2 3 4 5 6 7 8 Contents STX 0x02 MSB ALENGTH LSB ALENGTH COM ADR 0x31 STATUS 26 TAB SIZE 9 10 11 12 13 14 TAB START TAB LEN CRC16 TAB SIZE Maximum count of Transponde...

Page 113: ...ta Buffer clears the data sets from the data buffer which were transferred with the 12 4 0x22 Read Buffer command Host Reader Byte 1 2 3 4 5 6 7 Contents STX 0x02 MSB ALENGTH LSB ALENGTH COM ADR 0x32...

Page 114: ...fer clears the data buffer to an initial state It does not matter if the data sets in the data buffer were read or not Host Reader Byte 1 2 3 4 5 6 7 Contents STX 0x02 MSB ALENGTH LSB ALENGTH COM ADR...

Page 115: ...UHF Reader Manual ID ISC ANT U500 270 DM FEIG ELECTRONIC GmbH Page 115 of 117 H71011 0e ID B docx ANNEX ANNEX A Codes of Transponder Types Value Transponder type 0x84 EPC class 1 Gen 2 ISO 18000 6 C...

Page 116: ...parameters was exceeded 0x13 Login Request Configuration access without having logged in to the Reader before 0x14 Login Error Login attempt with wrong password 0x15 Read Protect The configuration blo...

Page 117: ...Diagnostic The antenna configuration isn t correct Check the antenna cables and the antenna matching The environment is too noisy The RF power doesn t have the configured value All RF channel are occu...

Reviews: