![background image](http://html1.mh-extra.com/html/feig-electronic/id-isc-ant-u500-270-dm/id-isc-ant-u500-270-dm_manual_3899834028.webp)
UHF-Reader
Manual
ID ISC.ANT.U500/270 - DM
FEIG ELECTRONIC GmbH
Page 28 of 117
H71011-0e-ID-B.docx
ACTIVE-STATE:
(DigitalIO.Output.NoX.ActiveState) x=2
Allocates a flashing-frequency to each output when a transponder was read.
Bit
15
14
13
12
11
10
9
8
Function
reserved
OUT2 frq
reserved
reserved
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
Bit combination
flashing frequency
b11
b10
b01
b00
1 Hz
2 Hz
4 Hz
No Flash (0 Hz)
IN-ACTIVE:
(DigitalIO.Input.NoX.Mode)x=2
Determines if the input is active with a closed or open contact:
b0:
closed contact activates input
b1:
open contact activates input
OUT2-TIME:
(DigitalIO.Output.No2.SettlingTime)
Defines the holding time of the digital output OUT2. If the Reader receives a valid Tran-
sponder response the antenna assigned to the output is activated for the value in OUT2-
TIME.
If OUT2 -TIME is zero the function is disabled.
If OUT2 is high in idle mode, OUT2 will low for OUT2-TIME.
If the flash mode is enabled, the output goes low.
Range: 0x00 ... 0xFF ( * 100ms) = 0s ... 25,6s.
NOTE:
Automated Reader Modes (reading of serial number and data):If the serial number was read
OK and the data not, no data set will be transferred, but the assigned OUT2 will be active.
Bit
7
6
5
4
3
2
1
0
Function
0
0
0
0
0
0
IN2
-