TR-DATA-3:
Selects the data types for read operation.
Bit
7
6
5
4
3
2
1
0
Function
-
-
-
-
READ_
COMPL
ETE_
BANK
-
-
-
READ_COMPLETE_BANK:
(
OperatingMode.BufferedReadMode.DataSelector.Mode.Read_Complete_Bank
)
(
OperatingMode.NotificationMode.DataSelector.Mode.Read_Complete_Bank
)
If this bit is set the reader will read out all memory blocks from the selected Memory BANK
starting from DB-ADR. If DB-
ADR is “0” the complete memory bank is read.
b00
Reader reads out the memory blocks according to the settings in DB-
ADR, DB-N, D-Start and D-LGT.
b01
Reader reads out all blocks of the selected memory bank starting at DB-
ADR
NOTE:
This functionality is has following limitations with respect to the individual memory banks:
EPC Memory:
max. 512 Bit
User Memory:
max. 16 kBit
TID Memory:
max. 512 Bit
Reserved Memory:
max. 64 Bit
The Read Complete Bank functionality is not available if Tag Authentication by Host with
TAM2 is enabled.
BANK:
Memory bank of the Transponder which will be accessed by the Reader
Bit
7
6
5
4
3
2
1
0
Function
0
0
0
0
0
BANK_NR
BANK_NR:
(
OperatingMode.BufferedReadMode.DataSource.BankNo
)
(
OperatingMode.NotificationMode.DataSource.BankNo
)