TR-DATA2:
Selects the data types for read operation.
Bit
7
6
5
4
3
2
1
0
Function
-
-
DIRECTI
ON
-
-
-
MAC
IN
IN:
Input states
MAC:
b0:
no MAC address will be transmitted
b1:
MAC address will be transmitted
DIRECTION:
b0:
no Direction states will be stored
b1:
Direction states will be stored