In case of Class 1 Gen 2 Transponder BANK_NR is defined as follows:
b000
reserved
b001
EPC memory bank
b010
TID memory bank
b011
User memory bank
DB-ADR
1
: (
OperatingMode.BufferedReadMode.DataSource.FirstDataBlock
)
(
OperatingMode.NotificationMode.DataSource.FirstDataBlock
)
Address of first data block. Range: 0x00...0xFF.
DB-N
5
: (
OperatingMode.BufferedReadMode.DataSource.NoOfDataBlocks
)
(
OperatingMode.NotificationMode.DataSource.NoOfDataBlocks
)
Number of data blocks. Range: 0x01...0x20. The data block size in the Buffered Read
Mode is always 2 bytes.
5
A plausibility check is performed by writing this parameter to the Reader. If an error occurs the Reader
answers with STATUS = [0x11].