![Feig Electronic ID ISC.ANT.U500/270-DM Manual Download Page 90](http://html1.mh-extra.com/html/feig-electronic/id-isc-ant-u500-270-dm/id-isc-ant-u500-270-dm_manual_3899834090.webp)
UHF-Reader
Manual
ID ISC.ANT.U500/270 - DM
FEIG ELECTRONIC GmbH
Page 90 of 117
H71011-0e-ID-B.docx
9.7. [0x74] Get Input
With this protocol the actual status of the digital input.IN2 can be determined at any time.
Host
Reader
Byte
1
2
3
4
5
6 .. 7
Contents
STX
(0x02)
MSB
ALENGTH
LSB
ALENGTH
COM-ADR
[0x74]
CRC16
Host
Reader
Byte
1
2
3
4
5
6
7
8 .. 9
Contents
STX
(0x02)
MSB
ALENGTH
LSB
ALENGTH
COM-ADR
[0x74]
STATUS
21
INPUTS
CRC16
INPUTS:
Bit
7
6
5
4
3
2
1
0
Function
-
-
-
-
-
-
IN2
-
b0
digital input = inactive
b1
digital input = active
NOTE:
If the trigger is enabled in Buffered Read Mode the input IN2 isn't available for common use.
21