UHF-Reader
Manual
ID ISC.ANT.U500/270 - DM
FEIG ELECTRONIC GmbH
Page 116 of 117
H71011-0e-ID-B.docx
ANNEX C: Index of Status Bytes
Hex-value
General
0x00
OK:
Data / parameters have been read or stored without error
Control command has been executed
0xF1
Hardware Warning:
RFC works not properly
RF Decoder or Hardware Filter works not properly
Hex-value
Parameter Status
0x10
EEPROM-Failure:
The EEPROM of the Reader is not able to be written on.
Before writing onto the EEPROM a faulty checksum of parameters has been detected.
0x11
Parameter-Range-Error:
The value range of the parameters was exceeded.
0x13
Login-Request:
Configuration access without having logged in to the Reader before.
0x14
Login-Error:
Login attempt with wrong password.
0x15
Read Protect:
The configuration block is reserved for future use.
0x16
Write Protect:
The configuration block is reserved for future use.
0x18
Wrong Firmware:
Mismatch between RFC Firmware and Hardware
Hex-value
Interface Status
0x80
Unknown Command:
The Reader does not support the selected function.
0x81
Length-Error:
The selected function has the wrong number of parameters.
0x82
Command not available:
A Host command was sent to the Reader in the Buffered Read Mode.
A Buffered Read Mode protocol was sent to the Reader in the standard mode.
The command with More bit does not correspond with the last command.