UHF-Reader
Manual
ID ISC.ANT.U500/270 - DM
FEIG ELECTRONIC GmbH
Page 41 of 117
H71011-0e-ID-B.docx
TRIGGER_X-HOLD-TIME:
x=2
(OperatingMode.BufferedReadMode.Trigger.Source.Input.NoX.HoldTime)
(OperatingMode.NotificationMode.Trigger.Source.Input.NoX.HoldTime)
(1 ... 65535 * 100 ms = 100 ms ... 6553,5 sec)
The TRIGGER-HOLD-TIME defines the period in which the Reader performs inventory
commands and holds the RF Power active.
NOTE:
The time the RF field stays on is depending on the combination of the Trigger Condition
and the Hold Time
ACTION:
defines actions in trigger mode.
Bit
7
6
5
4
3
2
1
0
Function
0
0
0
0
NO_READ_
SIGNALIZATION
RF-
OFF_AFTER
_READ
RF-OFF_AFTER_READ:
(
OperatingMode.BufferedReadMode.Trigger.Enable_RF-OffAfterRead
)
(
OperatingMode.NotificationMode.Trigger. Enable_RF-OffAfterRead
)
D
efines if the RF-Field is switched off after a read event
b0
disabled
b1
enabled
NO_READ_SIGNALIZATION:
(
OperatingMode.BufferedReadMode.Trigger.NoReadSignalization
)
(
OperatingMode.NotificationMode.Trigger.NoReadSignalization
)
Defines whether a signal emitter (OUT2) is activated if no transponder was de-
tected.
b000
no signal emitter will be activated
b010
OUT2 will be activated