![background image](http://html1.mh-extra.com/html/feig-electronic/id-isc-ant-u500-270-dm/id-isc-ant-u500-270-dm_manual_3899834088.webp)
UHF-Reader
Manual
ID ISC.ANT.U500/270 - DM
FEIG ELECTRONIC GmbH
Page 88 of 117
H71011-0e-ID-B.docx
OUT-NR:
Defines the Typ and the number of the output
Bit
7
6
5
4
3
2
1
0
Function
OUT-Typ
0
OUT-Number
OUT-typ:
b000
Digital Outputs
any other Bit configuration is reserved.
OUT-S:
OUT-S (Output State) defines the status of the output during the time defined in OUT-
TIME and provides the possibility to allocate its own flashing-frequency to each output.
Bit
7
6
5
4
3
2
1
0
Function
0
0
0
0
OUTx-frq
OUTx-mode
OUTx-mode:
b01
ON
output for OUT-TIME = active
b10
OFF
output for OUT-TIME = inactive
b11
FLASH
output for OUT-TIME = with OSF alternating
OUTx-frq:
b11
1 Hz
b10
2 Hz
b01
4 Hz
b00
8 Hz