UHF-Reader
Manual
ID ISC.ANT.U500/270 - DM
FEIG ELECTRONIC GmbH
Page 103 of 117
H71011-0e-ID-B.docx
OUT-S:
OUT-S (Output State) defines the status of the output during the time defined in OUT-
TIME and provides the possibility to allocate its own flashing-frequency to each output.
Bit:
7
6
5
4
3
2
1
0
Function:
0
0
0
0
OUTx-frq
OUTx-mode
OUTx-mode:
b00
UNCHANGED
OUT-TIME has no effect on the status of the output
b01
ON
output for OUT-TIME = active
b10
OFF
output for OUT-TIME = inactive
b11
FLASH
output for OUT-TIME = with OSF alternating
OUTx-frq:
b11
1 Hz
b10
2 Hz
b01
4 Hz
b00
8 Hz
OUT-TIME:
By the values defined by “OUT-TIME”, the outputs can be activated temporary limited or
unlimited.
An exception are the time values 0 and 65535 (0xFFFF) (see following table).
0x0001
1 x 100ms
-> 100ms
...
...
0xFFFE
65534 x 100ms -> 1:49:13 h
0xFFFF
continuously active
Notes:
In order to reset a continuously active time, OUT-TIME = 1 has to be sent to
the UPC, which effects a change to the idle status after 100 ms.
The continuous activation is being set back after a reset or a power failure.