![background image](http://html1.mh-extra.com/html/feig-electronic/id-isc-ant-u500-270-dm/id-isc-ant-u500-270-dm_manual_3899834040.webp)
UHF-Reader
Manual
ID ISC.ANT.U500/270 - DM
FEIG ELECTRONIC GmbH
Page 40 of 117
H71011-0e-ID-B.docx
Condition:
(
OperatingMode.BufferedReadMode.Trigger.Condition
)
(
OperatingMode.NotificationMode.Trigger.Condition
)
b0:
Level Triggered:
RF Field will be switched on with the rising edge. Trigger Hold Time
starts to run with the falling edge
b1:
Edge Triggered
RF Field will be switched on with the rising edge. Trigger Hold Time
starts to run with the rising edge.
Unlimited Valid Time:
(
OperatingMode.BufferedReadMode.Trigger.Enable_UnlimitTransponderValidTime
)
(
OperatingMode.NotificationMode.Trigger.Enable_UnlimitTransponderValidTime
)
b0:
Valid Time is limited to one Trigger Period:
The Valid Time (s. CFG12) is restarted with each Trigger Period and
thus not longer than one Trigger Period.
b1:
Unlimited Valid Time:
The Valid Time (s. CFG12) is applicable for more than one Trigger Peri-
od.
TRIGGER-USE:
Defines the start trigger.
TRIGGER-USE
Bit
7
6
5
4
3
2
1
0
Function
-
-
-
-
TU 2
TU-x: (
OperatingMode.BufferedReadMode.Trigger.Source.Input.NoX.TriggerUse
)
(
OperatingMode.NotificationMode.Trigger.Source.Input.NoX.TriggerUse
)
X is the input which is used as a trigger (X=2)
b00
trigger not used
b01
trigger start the Reader operation