Page 2: ...ny person for any special incidental indirect or consequential damages including without limitation damages resulting from use of or reliance on information presented herein or loss of profits or revenues or costs of replacement goods even if informed in advance of the possibility of such damages Trademarks IDENTEC SOLUTIONS Intelligent Long Range ILR and the stylized i are registered trademarks i...

Page 3: ...is transmitter must not be co located or operating in conjunction with any other antenna or transmitter Conformité à l exposition aux champs RF des équipements radio Pour satisfaire aux exigences FCC et ISED concernant l exposition aux champs RF pour les appareils mobile une distance de séparation de 20 cm ou plus doit être maintenu entre l antenne de ce dispositif et les personnes pendant le fonc...

Page 4: ...screw on the unit Best practice is to use an antistatic ribbon and earth yourself permanently for the time you handle the unit Avoid unnecessary contact with the unit connectors and assemblies inside the unit Only open the unit if the operational settings as described in the manual expressly requires it Use antistatic tools for the setting of the unit Warning Do not touch life threatening voltages...

Page 5: ...nd cool environments Do not open the Main housing The Connection Chamber can be opened for required cabling needs but there is no need to open the main housing crews from bottom side in order to set the iPOINT unit The unit does not have any internal setting elements or displays Connections Power Supply The supply circuits must comply with the conditions set out for the SELV circuits see EN 60950 ...

Page 6: ...USB Connector Pinout 15 2 4 USB Only mode Function and specification 16 2 5 Communication Interface Priorities 16 2 6 Lid Open Detection 16 3 Initial Operation Configuration 17 3 1 Status LEDs 17 4 Mechanical Information Installation 18 4 1 Opening the connection Chamber 18 4 2 Mounting Options 19 4 2 1 Optional Extra Pole Mount Bracket Kit 20 4 2 2 Optional Extra Extension Bracket Kit 21 5 Troubl...

Page 7: ...o the content contained herein It is the user s responsibility to contact the service department for any possible changes or updates to operating and maintenance procedures Updates will be provided upon request The information in this document may be subjected to changes without prior notice Check whether delivery is complete and for any damages If the delivery is not complete or damaged immediate...

Page 8: ...he Housing contains 5 Status LEDs see Section 3 1 a Connection Chamber where the wired interfaces can be accessed Relevant cable glands as wired access points depending on the device setup Mounting Plate and securing screw see Section 4 For a detailed description of how to correctly open the connection chamber and other mechanical information please refer to Section 4 1 The iPOINT can used as a st...

Page 9: ...ocols The iPOINT X has two internal UHF antennas built in and can communicate up to a range of 500 meters with its Tags The main benefit of two antennas is the elimination of RF dead spots in static systems 2 1 2 LF Interface The LF Interface uses IDENTEC s LFBOOST Marker technology Zone location at Low Frequency can be achieved with a configurable field range up to 5 Meters This allows Tag detect...

Page 10: ... reserved 10 2 1 3 NFC Interface The NFC Interface is a Near Field Communication interface The iPOINT can be used as an entry terminal or for other NFC communication The range to the Tag is around 10 15cm and is compatible with the i Q355 Series of Tags as well as standard NFC cards ...

Page 11: ...Tracking and Tracing Localization Environmental Data Sensing i B350 Tags IDENTEC SOLUTIONS i B350 tags are designed to be cost effective and easy to implement while offering maximum flexibility The beacon ILR Tags continually send out their ID at pre programmed intervals They do not need to be interrogated in order for them to send their information they do it automatically These active RFID tags ...

Page 12: ...tor for debugging low power operation and device configuration RS422 MASTER RJ45 RS422 cable connector to the host computer or previous Slave port in the daisychain RS422 SLAVE RJ45 RS422 cable connector to the master port of the next i PORT in the daisy chain Leave this connector open at the last device in the chain PoE Power installation For other system configurations please contact Identec Sol...

Page 13: ...ed 13 RS422 with injected 24V Power installation Make sure power supply can handle all iPOINTs in the system USB Mode 5V Local USB mode over Mini USB Connector for debugging low power operation and Configuration No Slave mode under USB operation Maximum power consumption of an iPOINT is 7W ...

Page 14: ...l units in the chain must not exceed 1000 m 3200 ft The distance from one unit to the next must not exceed 300 m 1000 ft This table is valid for Cat 5 cabling with gauge diameters of AWG24 0 25 mm of i PORTs Length m ft Remark 1 300 1000 Central supply with 24 VDC via the RS422 Master Slave 2 600 2000 Central supply with 24 VDC via the RS422 Master Slave 3 400 1300 Central supply with 24 VDC via t...

Page 15: ...er bus 8 GND GND Brown Power supply over bus As the TxD RxD crossing is done by the pinout of the connectors simple straight cabling has to be used Connection parameters Signal levels RS422 Baud rate 115200 bits per second Data bits 8 Stop bits 1 Parity none Mode half duplex 2 3 3 USB Connector Pinout A Standard Mini USB Cable and connector can be used to connect to the iPOINT Standard 5V power is...

Page 16: ...iver TBD Enter config debugging info 2 5 Communication Interface Priorities The priorities for the wired connections will be 1 USB Highest priority A connection over USB will terminate all other existing connections 2 Ethernet A connection via Ethernet PoE interface will terminate all serial connections 3 Serial RS422 Serial connections When a higher priority connection is disconnected bus access ...

Page 17: ...s Orange when a response or a broadcast is received LF This is the LF Communication LED LED blinks green when Marker Loop ID is sent It blinks red if LF is not working properly e g loop broken or loop current too low COM This is the wired interface LED It blinks green when a command is received and orange when responding over RS422 or RS485 Note Because of short communication you can see just the ...

Page 18: ...s from the front side until magnetic connection is released lift off 2 Loosen the 8x screws be aware DO NOT pull out the screws out completely the gasket can be damaged 3 Lift off the lid 4 Now you have access to the Connection Chamber Note when replacing the lid be sure that the sealing gasket is correctly in place Note The rest of the housing cannot be accessed There is no settings or modificati...

Page 19: ...nting plate only 4x countersunk screws are required with a maximum diameter of 5mm or M5 screws Length and type shall be chosen depending on wall material 4x countersunk screws Choose screw type and length depending on wall material Maximum diameter of 5mm Screw plate securely to the wall using all 4 screws the iPOINT device can then be clipped onto the plate and secured with the securing screw Wa...

Page 20: ...there s a risk of damage 4 2 1 Optional Extra Pole Mount Bracket Kit A Pole Mount Bracket Kit is available Pole Mount Bracket Kit o Contains the bracket and accessories o The bracket can be mounted to a wall with M8 Bolts or via threaded rods e g wall anchors o The bracket can also be mounted onto vertical or horizontal poles o Refer to Pole Mount Bracket Kit Quick Installation Guide documentation...

Page 21: ...Extension Bracket Kit is available Extension Bracket Kit o Contains the bracket and accessories o The bracket can be mounted to a wall with M8 Bolts or via threaded rods e g wall anchors o Multiple mounting options including use of the pole mount bracket o Refer to Extension Bracket Kit Quick Installation Guide documentation for more details ...

Page 22: ...iPOINT Hardware User Manual 18 06 2020 Copyright 2020 IDENTEC SOLUTIONS All rights reserved 22 ...

Page 23: ...depends on the relevant system concept and very likely varies from one system to another A Brief Checklist Are all housings intact Are all cables intact Are all connectors intact Are all connectors securely fastened Are all screws still tight Is there a sudden malfunction at a specific unit What are the status of the LEDs is the RUN LED flashing 6 Maintenance When installed correctly the iPOINT sy...

Page 24: ...n order to keep down times short it is recommended that these parameters are set before the component is entered into the spare part stock system In most cases all units within an identification system are used in the same way so that only one setting is required Examination and repair of exchanged parts The data ILR Tags and iPOINT X devices are complex electronic power units on which the custome...

Page 25: ... Interface USB USB Mini Status Display 5 LEDs UHF LF COM RUN NFC Electrical Power Source PoE 12 30VDC RS422 Master Power Consumption according to 802 3af3 Max 7 Watt Environmental Conditions Operating Temperature 40 C to 70 C 40 F to 158 F Storage Temperature 40 C to 85 C 40 F to 185 F Humidity Up to 50 non condensing open 100 closed Shock EN 60068 2 32 Multiple drops to concrete from 1m 3ft 5 tim...

Page 26: ...iPOINT Hardware User Manual 18 06 2020 Copyright 2020 IDENTEC SOLUTIONS All rights reserved 26 ...