![Fayat Group BOMAG BW 900-50 Service Manual Download Page 94](http://html1.mh-extra.com/html/fayat-group/bomag-bw-900-50/bomag-bw-900-50_service-manual_546898094.webp)
8.3
Pressure tests in the travel circuit
BOMAG
98
008 921 86
Evaluation of test
If the nominal value is not reached, check the
steering/charge pump.
6. Move the travel lever quickly forward and back-
ward, read the pressure gauges.
Nominal value
See technical data.
Evaluation of test
If the charge pressure drops below the nominal
value during the high pressure test, check the in-
dividual components.
If the specified high pressure is not reached,
check the travel pump.
If the starting pressure is reached to one travel di-
rection only, check the high pressure relief
valves.