9.2
Flushing - general
BOMAG
114
008 921 86
Before flushing
Change the filter element
Fig. 1
Clean the hydraulic tank
Fig. 2
!
Caution
Change the oil in case of excessive contam-
ination, oil discoloration or if the oil change
interval is almost due.
l
Filter the tank content with the filling and fil-
tering unit and pump it into an oil container.
l
Mark all hoses and disconnect them from
the hydraulic oil tank.
l
Clean the oil tank thoroughly from inside, if
necessary remove the tank cover.
l
Reconnect all hoses.
l
Fill the hydraulic oil tank again with the fill-
ing and filtering unit.
Bleeding
Fig. 3
l
Always bleed closed hydraulic circuits if
lines had been removed or connected.
Servicing the flushing filter kit
Fig. 4
l
Replace the filter element of the flushing fil-
ter when the red control pin of the contami-
nation indicator is pressed out during the
filtering process.
l
Clean hoses and connections and store the
flushing kit in a clean and protected envi-
ronment.