FARMSCAN Jackal Manual Download Page 8

 

 

 

AM-JACKAL-35/ JULY 2020 

TRACTOR HARNESS (CONTROL VERSION & SPRAY) 

 

Overview of Tractor Harness as below 

 

 

 

 

Connect to rear of Jackal 

Optional GPS Connection for 

Ground Speed 

12v – To 

Battery 

Sensor 

Connector 

Power 

Connector to 

Sensors 

Jackal Tractor 

Harness 

 

Part # 

AC-4501/T 

P2 - GREY 

P1 - GREEN 

Summary of Contents for Jackal

Page 1: ...JULY 2020 For Serial Numbers 7000 9999 ...

Page 2: ...ACHOMETER RPM METER SETUP WIZARD 25 FLOW METER SETUP WIZARD 27 SLIPPAGE METER WIZARD 30 RATE MONITOR LIQUID 31 RATE MONITOR SOLID 32 BATCH METER JACKAL CONTROL ONLY 34 BIN LEVEL SENSOR 36 AIR VOLT DEPTH TEMP PRESSURE SENSOR 37 TRIPS 40 ALARMS 41 INPUTS 42 GENERIC WIZARD 43 FRONT SCREEN 43 OTHER SETTINGS 44 OUTPUTS 45 GPS SERIAL 46 ABOUT JACKAL 46 DIAGNOSTICS 46 FACTORY RESET 46 WRITE YOUR SETTINGS...

Page 3: ...or pulses per unit or simply drive run a set amount whilst the unit is counting the pulses and let the system calculate its own factor 24 recordable trips allow the operator to track numerous jobs in a period of work and each input can be used to display information using imperial and metric units TECHNICAL SPECIFICATIONS Specifications below are subject to change and are based on a fully unlocked...

Page 4: ...T 10m extensions is available for purchase to extend the Parts 6 7 over a longer implement MOUNTING INSTALLATION The Jackal Monitor Spray Controller is provided with a suction window mount An optional RAM style is also available for purchase at an additional cost Farmscan Part No AH 407 RAM Slide mount onto unit and push sideways to lock into place Make sure you hear a click of the mount locking i...

Page 5: ...portant if required in the future 1 Connect power cable supplied DIRECTLY TO BATTERY 2 Ring terminals are used for battery connection and the bare end used to connect to the rear Jackal Refer above image for power connection 3 Connect Ground to BATT VE Terminal B11 using the RED with BLACK stripe wire 4 Connect 12 Volts battery terminal to BATT VE Terminal B10 using the RED wire 5 Ensure that the ...

Page 6: ...Prox Reed High Low On Off Alarm B4 INPUT 9 Prox Reed High Low On Off Alarm A5 INPUT 5 Prox Reed High Low On Off Alarm B5 12v OUT Supply Out Sensor Power A6 INPUT 6 Varying Voltage Sensor B6 OUT 6 Dump A7 GROUND Earth 0v B7 OUT 5 Section 3 A8 OUT 2 GND 12v Run Hold Alarm Freq Batch B8 OUT 4 Section 2 A9 OUT 1 GND 12v Run Hold Alarm Freq Batch B9 OUT 3 Section 1 A10 12v In 12v Battery B10 RS232 TX F...

Page 7: ... 12V BATTERY B10 RS232 TX A11 Ve IN BATTERY GROUND B11 RS232 RX Notes as below The Jackal sprayer harness is wired to suit the Farmscan control valve bank see below The Jackal Harness comes pre terminated with Packard plugs Pins o Adapter cables maybe purchased or included with some kits Page7 This cable can be modified for different valve bank assemblies Please refer to your implement supplier or...

Page 8: ...S CONTROL VERSION SPRAY Overview of Tractor Harness as below Connect to rear of Jackal Optional GPS Connection for Ground Speed 12v To Battery Sensor Connector Power Connector to Sensors Jackal Tractor Harness Part AC 4501 T P2 GREY P1 GREEN ...

Page 9: ...2v live when Jackal is on DO NOT SHORT Jackal Implement Sectional Harness Part AC 4501 S The Jackal Implement Harness allows for the following connections Sections 1 3 3 Wire Flow Control Valve 2 Wire Dump Optional Pressure Wheel Input Speed Tank Level Sensor Flow Meter 3 Wire NB The Jackal harness comes pre terminated with Packard s Kits purchased directly may include adapters as below Packard Ad...

Page 10: ...AM JACKAL 35 JULY 2020 8 SPRAY HARNESS OVERVIEW CONTROL VERSION SPRAY AC 7721 Packard to Section Valve AC 7722 Packard to Control Valve ...

Page 11: ... wire to either A7 or B1 and the white coloured signal wire into any A1 A5 or B3 B4 Use the wizard to setup the port and calibrate a sensor once installed THREE WIRE PROX SENSOR OR 3 WIRE FLOW METERS NEW SENSORS KIT AA 2011P AA 123P AA 125 AA 242 AA 230X AA 232X AA 231 These kits will all include a square wave type sensor The sensor is 3 wires and uses a ground earth wire a signal wire and a 12v p...

Page 12: ...RE BIN TANK LEVEL KIT 2060 A 2220P A 2221 These kits will all include an on off high low empty full type of sensor The analogue sensor is 3 wire and uses a ground earth wire a signal wire and a 12v power wire The diagram to the right shows which terminals to connect your sensors to Insert the ground wire to either A7 or B1 and the sensor wire into any A1 A5 or B3 B4 and the power wire to B5 Use th...

Page 13: ...filtered via an 80 mesh filter before the flow sensor to avoid foreign matter clogging jamming the turbine Chemicals may be introduced into the water stream without causing damage to the flow sensor but some chemicals may damage or reduce the solenoid diaphragm life particularly if undiluted REMOTE RUN HOLD ACTIVATE BY INPUT The Jackal can connect an external Run Hold trigger e g Remote Switch wir...

Page 14: ...tomotive relay Example Hella Automotive Relay 12v 30A 4RA003510 08 Pin 86 to A9 Out 1 Jackal 12v Run Hold Output Pin 85 to A7 Ground Pin 30 to 12v in Direct to Vehicle Battery Pin 87 to Positive Side of clutch switch Ensure negative ground on other side of switch returns to battery Enable the remote run hold out by From the front screen press SETUP Highlight OUTPUTS and press SELECT Highlight 1 NO...

Page 15: ...itor is active c When the monitor is in HOLD mode the unit displays the word HOLD BEEPS every 2 seconds 3 Page button a The PAGE button is used to scroll through BATCH mode screens or Spray Control functions 4 Select button 3 of a The Jackal has 3 buttons placed directly under the LCD These buttons will change function in different menus b The function of the button is indicated at the bottom of t...

Page 16: ...ckal can display one two or three lines of live information at any one time Using the middle NAV Enter button allows you to toggle between the different display modes when multiple inputs are being used Example 1 Line Example 2 Line Example 3 Line ...

Page 17: ...and edit the alarms Other Change speed input implement section widths external run hold Settings alarm notification settings beep on hold language options speed simulation for diagnostics Outputs This menu is used to control the Jackal outputs Refer to this manual and edit the outputs described ONLY to prevent damage to external sensors connected to the Jackal GPS Serial When an external GPS is co...

Page 18: ...riate harness connectors are supplied NB The following setup uses information from multiple pages in this manual SETUP AUTO MODE WIZARD MOST COMMON From the front screen press SETUP Highlight WIZARD and press SELECT Highlight Sprayer and Press NEXT Select Spray Mode Auto Requires Speed Flow Input Auto rate adjust Manual Adjust the Flow Control Valve Manually PAGE 18 Press NEXT to setup your Flow M...

Page 19: ... and be displayed Press NEXT Using the NAV EDIT keys highlight and edit the Quick set Rates Quick rate Step Value Press NEXT Using the NAV EDIT keys highlight and edit the HOLD STOP values as described below Press NEXT The Slow Hold Speed function is used to avoid loss of spray coverage caused by loss of pressure when travelling too slow or when reducing the target rate below the recommended minim...

Page 20: ...ress SKIP Press SKIP Press EDIT and change the number of sections required to control Press NEXT Using the NAV EDIT keys highlight and edit the section width values as required The Section Widths will also Total and be displayed Press NEXT Press SKIP Press NEXT to finalise the Wizard and return to the front screen When you return to the Front Screen the Jackal needs to display a value The value of...

Page 21: ...PAGE button Default Section On Off Control Run Screen Pre Set A B C Rate Screen Step Rate Adjust Flush Screen Alarm Trip Setup Layout DEFAULT RUN HOLD SCREEN Sections can be individually turned On OFF by pressing the soft keys underneath the sections numbers x Pressing the Run Hold button changes the Jackal from HOLD to RUN The LIVE rate in L Ha is displayed and if the desired target is reach OK w...

Page 22: ... If you believe the rate is not being maintained correctly when you speed up and slow down it s possible the Flow Control Valve is opening back to front Please refer to the OUTPUTS on PAGE 45 to swap the Outputs MANUAL RATE STEP ADJUST DURING FLUSH The Rate Rate STEP allows you to adjust your flow rate with the Pre Defined STEP rate previously input via the Wizard Your STEP can be changed via SETU...

Page 23: ...ximity Magnet Used with 2 3wire sensor Available Connections Refer to Installing Sensors from PAGES 9 11 NB The Implement harness has 3 wires by default If using our standard wheel sensor kit please only use the black colored wire The RED Positive does not need to be connected Trim this back or cover with heat shrink to prevent shorting out SETUP From the front screen press SETUP Highlight WIZARD ...

Page 24: ...is will divide the distance travelled by the number of pules registered MANUAL RATIO will now be updated to reflect the calibration factor Press NEXT Using the NAV buttons and pressing EDIT enter your implement width in m e g 12m Press NEXT Using the NAV buttons select how you would like the area to be displayed on the front screen Press NEXT You have the option to set Alarm Min Max points if requ...

Page 25: ...0 Press EXIT when done Press NEXT Using the NAV buttons and pressing EDIT enter your implement width in m e g 12m Press NEXT Using the NAV buttons select how you would like the area to be displayed on the front screen Press NEXT You have the option to set Alarm Min Max points if required Using the NAV buttons select and EDIT as required Press NEXT Change the input name if you desire Press EDIT Pre...

Page 26: ...ton to change the baud rate when the correct baud rate is selected the corresponding NMEA message will be acknowledged with a Y Press NEXT Using the NAV buttons and pressing EDIT enter your implement width in m e g 12m Press NEXT Using the NAV buttons select how you would like the area to be displayed on the front screen Press NEXT You have the option to set Alarm Min Max points if required Using ...

Page 27: ...ctions Refer to Installing Sensors from PAGES 9 11 SETUP From the front screen press SETUP Highlight WIZARD and press SELECT Highlight TACHOMETER and press NEXT Highlight and select the appropriate sensor INPUT and press NEXT Leave the default value of pulse rev and press NEXT Select MANUAL RATIO Select EDIT The manual ratio is the number of magnets or bolt heads teeth for proximity In most cases ...

Page 28: ...rm Min Max points if required Using the NAV buttons select and EDIT as required Press NEXT Change the input name if you desire Press EDIT Press NEXT Press NEXT to finalise the Wizard and return to the front screen THIS ENDS THE WIZARD SETUP FOR A TACHOMETER ...

Page 29: ...OR TAKE INTO ACCOUNT MULTIPLE SPRAY SECTIONS TURNING ON OFF TALK TO US ABOUT THE JACKAL CONTROL SERIES Sensors Required 3 Wire Flow Sensor Square Wave Available Connections Refer to Installing Sensors from PAGES 9 11 The example uses Input 2 Polmac Flow Sensor SETUP From the front screen press SETUP Highlight WIZARD and press SELECT Highlight FLOWMETER and press NEXT Highlight and select the appro...

Page 30: ...n the desired test volume has been reached press STOP Press CALC This will divide the measured amount by the number of pules registered MANUAL RATIO will now be updated to reflect the calibration factor Press NEXT Using the NAV buttons select how you would like the UOD to be displayed on the front screen Press NEXT You have the option to set Alarm Min Max points if required Using the NAV buttons s...

Page 31: ... to accept the new manual ratio PPL Using the NAV buttons select how you would like the UOD to be displayed on the front screen Press NEXT You have the option to set Alarm Min Max points if required Using the NAV buttons select EDIT as required Press NEXT Name the input if you desire Press EDIT or Press NEXT The Wizard is now complete Press NEXT You will be returned to the Front Screen THIS ENDS T...

Page 32: ...or wire is connected into on the rear of the Jackal press NEXT Press the EDIT button to change the baud rate when the correct baud rate is selected the corresponding NMEA message will be acknowledged with a Y Press NEXT As indicated drive above 3km hr Wheel input will then increment up displayed in Hz GPS speed will start to show As the system self calibrates the slip will get closer to 0 When the...

Page 33: ... the setup guide on page 27 for Flow Meter Setup 3 Follow the steps as described below From the front screen press SETUP Highlight FRONT SCREEN press SELECT Highlight the line in which the Flow Meter is connected to e g 3 Input 3 L min Press EDIT Highlight the UNIT press EDIT to change the unit to L Ha At no stage can the Jackal take into account multiple sections turning on an off and adjusting t...

Page 34: ...Have a bucket ready to catch the product c Have a set of scales e g Farmscan Part 2199 ready to weigh the product From the front screen press SETUP Highlight WIZARD press SELECT Highlight GENERIC WIZARD press NEXT Highlight the INPUT number where the sensor wire is connected into on the rear of the Jackal press NEXT Choose your unit of pulse by pressing the EDIT E g pulse kg Highlight TARGET press...

Page 35: ...NAV buttons select EDIT as required Press NEXT Name the input if you desire Press EDIT or Press NEXT The Wizard is now complete Press NEXT You will be returned to the Front Screen kg will now accumulate 2 Follow the setup guide on PAGE 21 for Speed Area Meter setup 3 Follow the steps as described below SETUP SOLID KG HA From the front screen press SETUP Highlight FRONT SCREEN press SELECT Highligh...

Page 36: ...uide on PAGE 27 for Flow Meter Setup From the front screen press SETUP Highlight FRONT SCREEN press SELECT Select an UNUSED front screen position press EDIT Press EDIT to select BATCH NB INPUT should match flow meter input Change if necessary Normally 2 Highlight UNIT press EDIT to change Unit to L Highlight TARGET press EDIT to change the batch volume required Using the NAV buttons enter the volu...

Page 37: ...ET Press RESET to clear the count value followed by START Water will flow and the batch will start to either count UP or count DOWN as selected START will toggle to STOP if you need to restart a batch RUN HOLD also performs the same action Press RESET if required If you need to keep a record of your batch press the PAGE button and press the TRIP button to save More about TRIPS on PAGE 40 TIP If yo...

Page 38: ... 1 5 or 8 9 to where the sensor wire is connected into on the rear of the Jackal press NEXT Press EDIT to change the unit to H L high low Other options include On Off Full Empty State will updated Live For example Low bin empty High bin full Test by placing hand around sensor Press NEXT Highlight the Unit of Display that you wish to be displayed on the front screen Press NEXT You have the option t...

Page 39: ... example uses Input 9 Liquid Pressure Sensor CALIBRATION MANUAL The example below details setting up a LIQUID PRESSURE SENSOR From the front screen press SETUP Highlight WIZARD press SELECT Highlight GENERIC WIZARD press SELECT Highlight the INPUT number 6 9 to where the sensor wire is connected into on the rear of the Jackal press NEXT Press EDIT to change the unit kPa psi bar Volt C i e kPa High...

Page 40: ...the option to set Alarm Min Max points if required Using the NAV buttons select EDIT as required Press NEXT Name the input if you desire Press EDIT or Press NEXT The Wizard is now complete Press NEXT You will be returned to the front screen THIS ENDS THE MANUAL SETUP FOR A VARAIBLE VOLTAGE INPUT SENSOR LIQUID ...

Page 41: ...n The voltage will now be displayed e g 1 75v In the above example we can set the minimum of 1kPa by HIGHLIGHTING EDITTING the values as required Press SET This will copy the live voltage into the CAL LOW voltage point Repeat the previous 2 steps for the CAL HIGH values Highlight or confirm the UOD Unit of Display e g kPa Press NEXT when done You have the option to set Alarm Min Max points if requ...

Page 42: ...bove allows you to SAVE RESET individual trips or view SAVED TRIPS By pressing the SAVE RESET you have the ability to Reset Trip Save Trip Reset All By pressing 2 Save Trip it will be stored in the SAVED TRIPS option You can now view the SAVED TRIPS You also have the ability to EDIT and name the Trip or DEL ALL Delete All Trips When you return to the TRIPS page the Trip will continue to accumulate...

Page 43: ...of 3000rpm Press EDIT to adjust these values Manual User setup Alarm points via the MENU FRONT SCREEN EDIT Input When the alarm point is reached e g over 3000rpm the line will FLASH notifying you of the alarm point Press ALARM to enter the page showing all Alarms active and inactive to reset the alarm REFER TO OUTPUTS ON PAGE 44 IF YOU WANT TO CONNECT AN EXTERNAL ALARM In the example above Line 1 ...

Page 44: ...ropriate port for your sensor RUN SCREEN SETUP INPUTS o Input 1 5 A1 A5 8 9 B3 B4 Square Wave o m ft yd in km mi pulse o pulse kg lb L gal bu rev bale unit each T m 3 o Full Empty On Off H L Input 6 7 A6 B2 Varying Voltage o Volt kPa psi bar volt C Once your inputs are setup and calibrated you now need to display them on the front screen ...

Page 45: ...rmats on the front screen You can have up to 3 line items per page and viewable at all times If more lines are added you can use the NAV buttons to scroll through each screen NB Selectable units realte to the input type E g Input 1 setup as a rev pulse could display rpm or hz as the unit From the front screen press SETUP Highlight FRONT SCREEN press SELECT Highlight the line you want to display th...

Page 46: ...nction As described on PAGE 11 12 By changing the Alarm Beep in seconds you can define how long audible Beeps can be heard during the Alarm alert before acknowledgment is required Press EDIT to change these options EDIT the AlarmOnHold from YES NO This option allows you to have alarms active while the Jackal is ON HOLD Change the Jackal to your local Language by pressing EDIT Simulate Speed allows...

Page 47: ...As described on PAGE 34 Control Only Section Sprayer Function Rate Sprayer Function Rate Sprayer Function Dump All Sprayer Function Dump Sprayer Function Clutch All Control Only Clutch Control Only Section Control Only Section Control Only Rate PWM Control Only Rate PVG32 Control Only Rate 5v Control Only Ratio Control Only Volt Varying Voltage 0 12v Control Only For further explanation of setups ...

Page 48: ...allows you to UNLOCK your Jackal to further functionality Please contact Farmscan should you wish to purchase an unlock code DIAGNOSTICS This screen provides the following information Voltage Displays a live input voltage to the Jackal Current Displays live Current draw on the Jackal Input x When inputs are enabled they will also be displayed for easy diagnostics FACTORY RESET WARNING This screen ...

Page 49: ...________________ USE THE CHART BELOW TO COLOUR CODE YOUR WIRING OR MAKE NOTES AGAINST EACH PORT A BOTTOM ROW GREEN PLUG B TOP ROW GREY PLUG A1 INPUT 1 B1 GROUND A2 INPUT 2 B2 INPUT 7 A3 INPUT 3 B3 INPUT 8 A4 INPUT 4 B4 INPUT 9 A5 INPUT 5 B5 12v OUT A6 INPUT 6 B6 OUT 6 A7 GROUND B7 OUT 5 A8 OUT 2 B8 OUT 4 A9 OUT 1 B9 OUT 3 A10 12v In 12v Battery B10 RS232 TX From GPS A11 Ve In Ground GND Battery B1...

Page 50: ...___________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________...

Page 51: ......

Page 52: ...7 Mordaunt Circuit Canning Vale WA 6155 AUSTRALIA SALES PH 61 8 6102 3200 SALES FAX 61 8 6102 3201 SUPPORT Powered by AgriSync Download the APP TXT or Call 0480 018 282 WST sales farmscan com au www farmscan com au 2020 Farmscan Pty Ltd AM JACKAL 35 JULY 10072020 ...