BATCH METER (JACKAL CONTROL ONLY)
The Jackal can be configured as a Batch
Meter to use a flow sensor and optional
solenoid valve to meter liquid volumes &
cease flow. The output of the Jackal is
suitable for direct connection to a 12V
solenoid valve.
Sensors Required:
•
Flow meter (any style)
•
1501 (Optional, from Farmscan) or
any 12V Solenoid Valve
Available Connections:
Refer to Installing Sensors from
PAGES 9-11
NB: The Jackal must be unlocked for controller for batch function to work.
SETUP
1.
Follow the setup guide on
PAGE
27
for “Flow Meter Setup”
From the front screen press
SETUP
Highlight
FRONT SCREEN
&
press
SELECT
Select an
UNUSED
front screen position & press
EDIT
Press
EDIT
to select
BATCH.
NB:
INPUT #
should match
flow meter input. Change if
necessary (Normally 2)
Highlight
UNIT
& press
EDIT
to change Unit to
L
Highlight
TARGET
& press
EDIT
to change the batch
volume required.
Using the NAV buttons enter
the
volume required.
Press
EXIT
when done
Using the NAV buttons press
DOWN
and
EDIT
the
COUNT
to batch
UP
or
DOWN
.
Press
EXIT
when done
Press
EXIT
again
CONTIUNE INSTRUCTIONS IF
A SOLENOID IS INSTALLED OR
SKIP TO OPERATION
Highlight
OUTPUTS
& press
SELECT
Highlight 2: None & Press
SELECT
to edit Output 2
Press
EDIT
and change the
MODE to
BATCH