AM-JACKAL-35/ JULY 2020
22
CALIBRATION (AUTO SET)
1.
Ensure that the sensor and pickup are end-end before continuing
2.
Mark bottom centre of tyre on which the sensor is fitted and peg ground in corresponding position
3.
Measure out a known distance to calibrate i.e. 20m-100m
4.
Peg the corresponding point i.e. at the 20/100m mark
Select
TARGET
Select
EDIT
Using the
NAV
buttons enter
your measured distance. i.e.
20.0000
Press
EXIT
when done.
Press
START
and move
forward slowly.
This will allow pulses to
register.
When you arrive at the
center mark point of tyre to
peg press
STOP
Press
CALC.
This will divide
the distance travelled by the
number of pules registered.
MANUAL RATIO
will now be
updated to reflect the
calibration factor.
Press
NEXT
Using the NAV buttons and
pressing
EDIT
enter your
implement width in (m). e.g.
12m
Press
NEXT
Using the
NAV
buttons
select how you would like
the area to be displayed on
the front screen.
Press
NEXT
You have the option to set
Alarm Min/Max points if
required. Using the
NAV
buttons select and
EDIT
as
required. Press
NEXT
Change the input name if you
desire, Press
EDIT,
Press
NEXT
Select either
YES
or
NO
to
display Speed on the front
screen with the area covered.
Change the input name if
you desire, Press
EDIT
Press
NEXT
Press
NEXT
to finalise the
Wizard and return to the
front screen
THIS ENDS THE AUTO SET WIZARD SETUP FOR SPEED/AREA METER