Explanation of Components
SPLIT SECOND SPRAY LINE (INDIVIDUAL MODE)
A split second spray line is necessary when sections are frequently shutdown during operation.
A split second spray line requires a separate section valve for each section of the second spray line.
Each second line section valve must feed the matching width as covered by each first spray line section
valve.
The first and second spray line section valves should be plumbed onto a common manifold and must tee
off the main delivery line after the flow sensor and flow control valve.
3 wire motorised valves:
Red = +12V
Black = Negative
Colour = Trigger