Installation of Terminal – Smart Switch - UniPOD
MOUNTING THE UNIPOD
A UniPOD (ECU) & sensor adapter harness (AC-740X) is supplied with all systems to provide connection
points for sensors.
Ensure the UniPOD is mounted as per example below.
Ensure that all cabling leaving the UniPOD faces downwards, so as to prevent water entering the
UniPOD or connections.
It is recommended, if possible, to mount the UniPOD in a position sheltered from the weather.
Refer to
Page 100
for UniPOD Pinouts
UNIPOD STAUS LIGHTS
The UniPOD has two (2) status indicator lights located at the top right hand side of the UniPOD mainboard
(inside the enclosure). This should be left visible at all times for troubleshooting.
RED
(SOLID): 12v Power is connected to the UniPOD
GREEN
(SOLID): Fixed CANbus communications to 7000
RED
/
GREEN
(FLASHING): Run Mode
Status Lights
GREY
Connector
BLACK
Connector