ORIGINAL INSTRUCTIONS TRANSLATION
Pag.
di
15
17
CHAP. 5.
MAINTENANCE, BREAKS RESEARCH AND CLEANING
MAINTENANCE MAN REQUIREMENTS
With the term “
maintenance
” must not be understood only the periodical check of the machine normal functioning but also
the analysis and the consequent remedy of all causes that for any matter put it out of service. It is absolutely necessary that for
the
maintenance, cleaning, parts change and breaks research
activities performed from the user,
this work is entrusted to
skilled personnel
, competence and authorized from the employer.
All operations of
maintenance, cleaning and parts change
, none excluded, must be definitely performed with the machine
completely stopped and insulated from the external feeding sources.
MAINTENANCE PRESCRIPTIONS, DAMAGES RESEARCH AND CLEANING
PROTECTIONS REMOVAL AND/OR PROTECTION DEVICES
For the interventions of the present
charter, it isn’t necessary to remove from their position both fixed shelter both
moving one.
INSULATION FROM THE EXTERNAL FEEDING SOURCES
Before to perform any operation of
maintenance, cleaning and parts change
, the external feeding sources must be sectioned
and insulated:
1.
Position on “zero” the protection device placed upstream of the electric equipment feeding line.
2.
Disconnect the general sectioning device and provide to protect the plug with proper systems
3.
Close the drinking water tap,
4.
Slacken and unscrew completely the drinking water flexible pipe union from the tap.
BREAKS OR DAMAGES RESEARCH AND MOVING ELEMENTS UNBLOCKING
Here follow are indicate the interventions for the
breaks or damages research and moving elements unblocking
which can
be
performed from maintenance men
.
TYPE
POTENTIAL CAUSE/S
MODALITY AND COMPARISONS
Net voltage
lacking
General Black out
Contact the electric energy distributor
Fuses or magneto thermals intervention
place upstream of the machine feeding
line
After having eliminated the causes that have determined the protection device
intervention, restore it. In case of problem persistency contact an electrician
technician.
Functioning
intervention
Protection device intervention inside
the machine
Contact an electrician technician: after having eliminated the causes that have
determined the protection device intervention, restore it.
In case of fuses intervention,
change them with types of the same model,
calibration and intervention curve.
Unblock and opening of the
transparent superior cover or of the
discharge lateral door (if any)
Unblocking and opening the cover or the door, the machine stops immediately
for the safety micro switches functioning.
Close and block the cover and the door handles.
Cause/s not identifiable
Contact directly the Authorized Assistance Center
The machine
doesn’t function:
the flat doesn’t
rotate
Feeding voltage lacking.
Sectioning devices on “O”.
Lacked working time setting
Intervened fuses or not functioning
magneto thermals.
Lacked buttons functioning.
Damaged micro switches
Slow drive belt determines also noise
or creaking emission
Check and restore the electric energy.
Turn the sectioning devices in the position “ON ”
Set the timer in the controls panel
Change the intervened fuses, check the magneto thermal switches condition.
Check the buttons efficiency and eventually contact directly the Authorized
Assistance Centre.
Contact directly the Authorized Assistance Centre
Contact directly the Authorized Assistance Centre
The potatoes peel
or the mussels
scrape don’t
happen in a
correct way.
Worn flat surface
Abrasive cloth surface inside the worn
basin
Contact directly the Authorized Assistance Centre for the change
Contact directly the Authorized Assistance Centre for the change
Drinking water
absence inside the
basin during the
functioning
Drinking water flexible pipe not
connected
Tap closed
Water emission nozzle inside the
obstructed basin
Damage in the plant inside the machine
Connect the drinking water flexible pipe, screwing the piping union to the tap
male joint
Rotate the superior part in clockwise for the drinking water flow
Perform the nozzle holes cleaning as showed, with the switched off machine
and insulated from the external feeding sources
Contact directly the Authorized Assistance Centre
Excessive water
presence inside
the basin that
doesn’t discharge
or splash in the
machine inferior
zone
Dross separation filter obstructed
Drawer in steel in the body inferior
zone mal inserted
Presence of losses from the lateral
discharge pipe union
Perform the cleaning as showed in the appropriate chapter
Insert on the drawer bottom so that the basin discharge happens completely
inside the drawer
Discharge pipe not inserted correctly or not blocked with strip
Summary of Contents for 5 kg
Page 18: ......
Page 35: ......
Page 52: ......
Page 69: ......
Page 86: ......
Page 87: ...Pag di 2 18 1 3 2 4 3 8 4 10 5 15 6 18 7 18 12 1 2 3 4 5 2015...
Page 88: ...Pag di 3 18 1 1 2 3...
Page 89: ...Pag di 4 18 2 1 2 3 4 5 5 6 5 7...
Page 91: ...Pag di 6 18 1 2 3 4 5 6 7 8 9 5 mm 385mm 385mm 5 385mm...
Page 92: ...Pag di 7 18 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 10 18 18 19 20 21 22...
Page 93: ...Pag di 8 18 3 1 2 89 654 CEE 89 391 CEE 1 2 3 10 18 1...
Page 94: ...Pag di 9 18 3 4 1 2 3 4 6 5 10 18 10 18...
Page 95: ...Pag di 10 18 1 2 10 18 1 2 3 4 5 1 2 3 4 N 5...
Page 96: ...Pag di 11 18 OFF ON 1 2 3 4 5 6 1 2 3 5...
Page 97: ...Pag di 12 18 OFF 1 1 2 2 3 3 4 4 5 O I 10 1 10 1...
Page 98: ...Pag di 13 18 I O 10 18 10 18 5...
Page 99: ...Pag di 14 18 1 2 10 18 3 4 5 6 I 7 I O 5 5 10 18 1 2 3 4 5 1 2 OFF 3 4 5...
Page 100: ...Pag di 15 18 4 1 2 3 4 black out OFF ON...
Page 101: ...Pag di 16 18 2 1 2 10 3 4 5 10 6 7 8 9 10 18 3...
Page 102: ...Pag di 17 18...
Page 103: ...Pag di 18 18 5 6 AISI 304 10 18...