4-3
Digital XPoint Matrix Switchers
•
Programmer’s Guide
Login Administrator
Login User
The switcher initiates the login message when a correct administrator or user
password has been entered. If the user and administrator passwords are the same,
the switcher defaults to administrator privileges.
Reconfig
The reconfig message is initiated by the switcher when a front panel operation has
occurred, an audio gain adjustment has been completed, or a memory preset has
been recalled.
All Configuration Memory Cleared
The memory cleared message is initiated by the switcher when a system reset has
occurred. See System reset to factory defaults in chapter 3.
The switcher does not expect a response from the host, but the host program might
request a new status.
Switcher Error Responses
When the switcher receives an SIS command and determines that it is valid, it
performs the command and sends a response to the host device. If the switcher is
unable to perform the command because the command is invalid or contains
invalid parameters, the switcher returns an error response to the host. The error
response codes are:
E01 — Invalid input channel number (too large)
E10 — Invalid command
E11 — Invalid preset number (too large)
E12 — Invalid output number (too large)
E14 — Illegal command for this configuration
E24 — Privilege violation
Using the Command/Response Table
The command/response table begins on the next page. Upper- or lowercase letters
are acceptable in the command field. Symbols are used throughout the table to
represent variables in the command/response fields. Command and response
examples are shown throughout the table.
The table below shows the hexadecimal equivalent of each ASCII command.
ASCII to HEX Conversion Table