4.1.4.
Timecode Status Window
Introduction
This page of the Server Monitoring section provides information on the genlock, analog
LTC and timecode statuses from the EVS server. This page is also used to set up how the
timecodes are managed in the timecode jump tables.
Genlock Status
The Genlock Status section provides the following information:
•
Genlock status: OK, bad
•
Date and time when the genlock has been correctly set or restored.
Analog LTC Status
The Analog LTC Status section specifies the current status of the analog LTC timecode,
as well as the number of drifts detected compared to the genlock.
The possible status values are the following depending on the MTPC board used:
Status
Description
OK
The timecode is incremented in a normal way.
Drift
The timecode received and the genlock are not synchronous.
Bad
The timecode received is not correct.
For example when an NTSC timecode is received instead of a PAL
timecode (freq. error), when there are disturbances in the timecode
reception (bad signal).
Lost
No timecode is available.