Possible incidents
Causes
Corrective actions
The
pictogram is displaying
The temperature has
not returned to within
the ±4 °C threshold
Check that the door is correctly closed.
Check the condition of the door seal.
If you placed a large amount of bottles in your cabinet in the last few hours,
wait a while then check again. If the alarm is still displaying, contact your
EuroCave Professional retailer.
The
pictogram is still displaying
even though I have taken the corrective
actions above
Operating fault
Unplug the cabinet and contact your EuroCave Professional retailer.
The
pictogram is displaying
Open door alarm
Make sure that the door is correctly closed.
The
pictogram is flashing
The level of relative
humidity has been <
50 % for over 72 hrs
• Pour a glass of water into the duct of the tray (see chapter 7, § IV).
• In order to know how often to add water, count the number of days
separating the 1st day you added water and the day when the pictogram was
displayed
After a few hours, the pictogram will disappear.
The appliance cannot lower the level of
humidity to the desired value
• Empty the cabinet, remove the humidity cartridge and clean the tray.
• Remove the tube placed at the back of the tray. The humidity will be directly
discharged out of the appliance.
Call the EuroCave Professional retailer if the problem persists despite having
carried out these different operations.
The
pictogram is displaying
Charcoal filter alarm
Replace the charcoal filter (see chapter 4).
The
pictogram is displaying
Temperature sensor
fault alarm
Contact your EuroCave Professional retailer.
If your appliance does not seem to be working correctly, contact your EuroCave Professional retailer.
Standards
Your product complies with the following standards:
1- S
afety
- Directive 2006/95/CE
Standards
EN60335-1: Version 5 - 2010 +A1 + A2 + A11 + A12 + A13
EN60335-2-89
2- eMC
- Directive 2004/108/CE
Standard
EN55014-1/2
3- e
nvironMent
- Directive 2010/30/EU
Directive
2010/30/EU
Regulation
1060/2010
R600a
Depending on the country, EuroCave
wine cabinets may contain flammable
refrigerant gas (R600a: ISO BUTANE).
6000
Height
1
Width Depth
2
Weight when empty
Electrical power
3
(Watts)
Recommended
temperature range
mm
mm
mm
Full Glass door
(Kg)
Glass door (Kg)
Solid door (Kg)
Min T°(°C / °F) - Max T° (°C / °F)
230V-50Hz
(R600a gas)
115V-60Hz
(R134a gas)
Glass
Solid door
1 temperature
6182V
1825
680
690
96
94
89
75
105
0-30 / 32-86
0-35 / 32-95
6074V
960
680
690
60
58
56
65
95
0-30 / 32-86
0-35 / 32-95
2
temperatures
6170D
1825
680
690
100
98
93
65
95
10-30 / 50-86
10-35 / 50-95
Multi-temperatures
6182S
1825
680
690
94
92
87
75
105
12-30 / 54-86
12-30 / 54-86
6074S
960
680
690
58
56
54
70
95
12-30 / 54-86
12-30 / 54-86
Control accuracy: +/- 1°C (2°F), display accuracy: +/- 1°C (2°F).
1- Height including the top hinges and the feet, adjusted to mid-height.
2- Depth including a gap of 29 mm at the back of the cabinet for ventilation.
3- Electrical power per 24hrs measured with an external temperature of 25°C / 77°F and a solid door.
9 - e
neRgy
And
teChniCAl
FeAtuRes
8 - o
PeRAting
FAults
9 - e
neRgy
And
teChniCAl
FeAtuRes
Data relating to European regulations on power consumption
Ref.
Types of doors
Energy
efficiency
rating
1
Annual energy
consumption AEc
2
(Kwh/an)
Useful
volume
(litres)
Acoustic emissions
(dB(A))
6000
230V-50Hz
(R600a gas)
115V-60Hz
(R134a gas)
230V-50Hz
(R600a gas)
115V-60Hz
(R134a gas)
1 temperature
6182V
Solid
A+
128
183
445
37
38
6182V
Full Glass
A
165
256
445
37
38
6182V
Glass
A
165
256
445
37
38
6074V
Solid
A+
114
165
210
37
38
6074V
Full Glass
A
146
219
210
37
38
6074V
Glass
A
146
219
210
37
38
2 temperatures
6170D
Solid
A+
128
183
430
37
38
6170D
Full Glass
A
165
256
430
37
38
6170D
Glass
A
165
256
430
37
38
Multi-temperatures
6182S
Solid
A+
128
183
460
37
38
6182S
Full Glass
A
165
256
460
37
38
6182S
Glass
A
165
256
460
37
38
6074S
Solid
A+
114
165
225
37
38
6074S
Full Glass
A
146
219
225
37
38
6074S
Glass
A
146
219
225
37
38
1- Only concerns 230V-50Hz models (R600a gas).
2- Power consumption calculation based on the result obtained over 24 hrs in standard test conditions (25°C/77°F). Actual power consumption depends on
the appliance’s location and operating conditions.
This appliance is intended exclusively for wine storage.
Category of all models: 2
Climate class: Our appliances are designed for use at an ambient temperature of between 10°C and 32°C (50°F and 90°F) (Class SN). Nevertheless, refer to
the technical properties tables (p16) for the optimal performance levels of your product..
These appliances cannot be built-in.
3- red serving temperature
The use of glass doors can alter your wine cabinet’s performance
in some extreme temperature conditions.