45
PROBLEM
CAUSE
SOLUTION
Not enough suction on the squeegee
88.
Recovery tank is full
89.
Lid on the exhaust pipe is open
90.
Vacuum pipe disconnected
91.
Vacuum pipe is clogged
92.
Faulty vacuum pipe
93.
Dirty squeegee
94.
The squeegee is not adjusted properly
95.
Material tangled with the squeegee blades
96.
Squeegee blades either broken or worn out
97.
The tank is either open or not properly closed
98.
Damaged lid gasket
99.
Faulty suction motor
100.
Flat batteries
Empty the tank
Tight the lid
Verify that it is mounted properly
Clean the vacuum pipe
Replace the pipe
Clean the squeegee
Adjust inclination and pressure
Clean the blades
Reverse the blade or replace them
Close or verify the lid
Replace the gasket
Replace or check the motor
Recharge them
Front lights and side lights not working
101.
Light faulty
102.
Switch faulty
103.
Fuse carrier 10A fuse pos.8 faulty
104.
Transformer no. 2 faulty
105.
Service supply remote switch faulty
Replace
Have it replaced
Replace it
Replace it
Have it replaced
Stop lights not working
106.
Light faulty
107.
Micro switch on brake pedal faulty
108.
Fuse carrier 10A fuse pos.8 faulty
109.
Transformer no. 2 faulty
110.
Service supply remote switch faulty
Replace
Have it replaced
Replace it
Replace it
Have it replaced
Reverse lights not working
111.
Light faulty
112.
Reverse light relay faulty
113.
Fuse carrier 5A fuse pos.7 faulty
114.
Fuse carrier 10A fuse pos.6 faulty
115.
Transformer no. 1 faulty
116.
Service supply remote switch faulty
Replace
Have it replaced
Replace it
Replace it
Have it replaced
Have it replaced
Reverse buzzer not working
117.
Buzzer faulty
118.
Fuse carrier 10A fuse pos.6 faulty
119.
Transformer no 1 faulty
120.
Service supply remote switch faulty
Have it replaced
Replace it
Have it replaced
Have it replaced
Flashing lights not working
121.
Lights faulty
122.
Fuse carrier 3A fuse pos.5 faulty
123.
Fuse carrier 10A fuse pos.6 faulty
124.
Intermittence faulty
125.
Transformer no.1 faulty
126.
Service supply remote switch faulty
Replace
Replace it
Replace it
Have it replaced
Replace it
Have it replaced
Tank inspection cover does not open
127.
Suction unit on
128.
Toggle switch faulty
129.
Toggle switch connector disconnected or badly
connected
130.
Relay faulty
131.
Fuse carrier 3A fuse pos.10 burnt out
132.
Service supply remote switch faulty
133.
Fuse carrier 30A fuse pos.3 burnt out
134.
Actuator faulty
Switch off suction unit
Replace switch
Check the connector connection
Have it replaced
Replace it
Have it replaced
Replace it
Have it replaced