34
CLEANING THE SOLUTION PIPE FITTING
1
2
3
4
5
The machine is fitted with a metering pump for clean water and a metering pump for detergent.
If the solution does not flow out of the tank properly, make sure the output pipe fitting is not obstructed or clogged
(pos.1and 2).
POS.1: detergent output pipe fitting;
POS.2: clean water output pipe fitting.
To check that proceed as follows:
Bring the machine into a stop position in a flat surface area and put on the brake;
Lower the brush plate pos.3 by pressing the special button in the control board;
With the lowered plate, turn off the machine and remove the key;
Press the emergency button (pos.5) so as to interrupt supply.
Unscrew the cap manually pos.3 OR POS. 4;
Use a thin piece of wire of approximately Ø2-3 mm and remove any incrustations from the pipe fitting pos.1 or pos.2;
Mount the cap;
Pull the emergency button upwards;
Insert the key and turn it towards the ignition
After some seconds, the machine will lift automatically the plate and it will be ready to start working.