Section 9: Dynamics
9 - 34
Euphonix CS3000/2000 Operation Manual
Page 1 Numeric Keypad
Select Compressor/Gate
Below is the DSC Numeric keypad mapping for compressor and gate param-
eters and the available range for each parameter. Note that the available
range of some parameters is sometimes dependent on where other param-
eters are set (e.g., the range of possible values for Compression Knee can be
affected by the Threshold setting).
Page 1 Parameters
Keypad # Parameter
Options or value range
Type
0
Gate Depth
-80 dB to
0 dB
Rotary
Enter
Gate Threshold
-40 dB to
+10 dB
Rotary
Del
Input Level
-6 dB, 0 dB, +6 dB, +12 dB
Switch
1
Gate Attack
10
µ
s
to
1 s
Rotary
2
Gate Release
2 ms
to
4 s
Rotary
3
Gate Hold
2 ms
to
2 s
Rotary
4
Compression Ratio
1:1
to
∞
:1
to
-1:1
Rotary
5
Compression Threshold
-40 dB to
20 dB
Rotary
6
Compression Knee
0 dB
to
30 dB
Rotary
7
Compression Attack
100
µ
s to
1 s
Rotary
8
Compression Release
1 ms
to
10 s
Rotary
9
Compression Makeup Gain
0 dB
to
24 dB
Rotary
L1
Filters
In
or
Out
Switch
L2
Gate
In
or
Out
Switch
L3
Compressor
In
or
Out
Switch
L4
Dynamics Processor
In
or
Out
Switch
+/–
Dynamics Page #
Page 1 or
Page 2
Switch
7
8
9
4
5
6
1
2
3
0
Enter
Del
Compressor
Gate
Release
Makeup Gain
Ratio
Attack
Release
Hold Time
Threshold
Knee
Attack
Threshold
Depth
Input Level
(Main Input and Side Chain)
Summary of Contents for MixView CS2000
Page 1: ...CS3000 CS2000 Operation Manual Version 3 0 Revision 1...
Page 14: ...Table of Contents xiv Euphonix CS3000 2000 Operation Manual This page intentionally left blank...
Page 303: ...Euphonix CS3000 2000 Operation Manual A 1 A APPENDICES EUPHONIX MIXING SYSTEMS...
Page 304: ...A 2 Euphonix CS3000 2000 Operation Manual This page intentionally left blank...
Page 315: ...Index CS3000 2000 Operation Manual I 1 I INDEX EUPHONIX MIXING SYSTEMS...
Page 316: ...I 2 CS3000 2000 Operation Manual Index This page intentionally left blank...
Page 324: ...I 10 CS3000 2000 Operation Manual Index This page intentionally left blank...