14
Kongsberg XP
3.
Repeat for each fuse.
4.
Replace base cover
5.
Insert main power cable into the wall socket and turn main power on.
Fuse Details
All fuses are: 1 1/4 x 1/4 in (6,3 x 32 mm)
Fuse location
115V
230V
Line fuses F1 and F2
T 15A 250V
T 6,25A 250V
200V Servo power fuse F200
T 15A 250V
T 15A 250V
48V Servo power fuse F48
T 8A 250V
T 8A 250V
+24V fuse F4
T 6.25A 250V
T 6.25A 250V
14.2. X1
X1 Amplifier Location
180