12
Kongsberg XP
Extreme care should be taken when inserting the
Knife Foot
again.
Keep fingers away from
Knife Blade
as illustrated
at left.
Tool Adjustment
For this tool, complete the following adjustments:
Adjustment
Description
Lag Setting
The
Knife Lag
depends upon the
Blade Adapter
.
Nominal value is 0-3 mm.
Tool Height
Measured automatically, possible to add an
Offset Value
.
Tool Rotation
Adjust
Tool Angle
tangential to
Moving Direction
.
Center Offset
Adjust
Tool
sideways until centered.
Tool Offset
Adjust offset relative to
Laser Pointer
.
For more information about how to run the
Adjustment Wizards
Replace Knife Adapter
To remove the
Knife Adapter
, just pull it out from
the holder.
147