Epson Research and Development
Page 13
Vancouver Design Center
13704CFG.EXE Configuration Program
S1D13704
Issue Date: 01/02/08
X26A-B-001-02
• Bypass LUT – when selected this option causes the lookup table to be bypassed.
Selecting to bypass the lookup table results in a power saving as the lookup table section
of the S1D13704 is powered down when this option is selected.
This option is only applicable for monochrome displays. If a color panel is selected this
option is disabled.
When the lookup table is not enabled then display intensities are dependent on the
values in the lookup table. A smaller numerical value in display memory may be
displayed with a greater intensity than a larger value.
When the lookup table is bypassed the colors displayed on the panel are directly propor-
tional to their memory value. (i.e. at 4 bit per pixel; 00h will display as black and 0Fh
will display as full intensity)
Open
Click on the Open button to read the settings saved in an executable program based on the
S1D13704 hardware abstraction layer.
Clicking the Open button brings up the standard Windows file open dialog.
Figure 8: 13704CFG File Open Dialog
From here the user selects the file to be opened. 13704CFG is capable of opening
executable files based on the S1D13704 HAL. Typically the file extension for these file are
.EXE for intel platform executables and .S9 for 68k and SH3 platform executables.
*