![Epson LQ-300 - Impact Printer Service Manual Download Page 71](http://html.mh-extra.com/html/epson/lq-300-impact-printer/lq-300-impact-printer_service-manual_109402071.webp)
Disassembly and Assembly
Service Manual
3.2.4.5
Removing the
Sensor
1.
Remove theprinter mechanism (see Section 3.2.4).
2. Release the 2 clips attaching the HP sensor and remove it. The clips
be accessed
2
holes in the base frame. To release the clips, push each with a pair of tweezers.
Base
Figure 3-14. Removing the HP Sensor
3.2.4.6 Removing the Release
Lever Position
Sensor
1. Remove the
assembly (see Section 3.2.4.1).
2. Release the 2 clips that attach the release lever position sensor to the frame of the
motor
assembly.
3. Remove the release lever position sensor from the frame of the
assembly.
Frame of the
Release Lever
PF
Motor
Position Sensor
Clip
Figure 3-15. Removing the Release Lever Position Sensor
3-14
Summary of Contents for LQ-300 - Impact Printer
Page 1: ...EPSON TERMINAL PRINTER LQ 300 SERVICE MANUAL EPSON ...
Page 5: ...REVISION SHEET Revision Issue Date Revision Page Rev A September 28 1994 1st issue f v 1 ...
Page 34: ...c f ...
Page 101: ...Maintenance LQ 300 Service Manual Figure 6 1 LQ 300 Lubrication Points 6 2 Rev A ...
Page 110: ... Figure A 6 C130 PSB PSE Component Layout ...
Page 112: ...Appendix LC MMS vbeMantd Q ix iyii t v Figure A 8 LQ 300 Exploded Diagram 2 A 12 Rev A ...
Page 119: ... f ...