Solimotion FTR20
Commissioning
Hauser
45
The damping is configured as follows:
Move the encoding switch to position A
→ Display of the function number
→ After 2 seconds: Display of the configured damping, example:
(damping = 200 ms)
Press the or
key on the device to configure the damping
→ Display of the changed damping, example:
(damping increased to 500 ms)
Move the encoding switch to the initial position 0
→ Display of the current signal strength
• The set time not only damps the signal strength display, but also impacts the switch output
(for example, a delayed switching) and the current output (rises/falls with a delay).
• If only the switch output is to be stabilized, it is advisable to configure a switch-on and/or off
delay (→
42
).
• The switch-on and/or off delay and damping can be combined, which causes the detection
to be significantly slower.
8�5
Resetting to factory defaults (function F)
You can reset the Solimotion FTR20 to its factory defaults with this function as follows:
Move the encoding switch to position F
→ Display of the function number
→ All LEDs go out after 2 seconds.
Press the and keys on the device to set it to the factory defaults
→ All LEDs illuminate as confirmation.
Move the encoding switch to the initial position 0
→ Display of the current signal strength
Function
Description
Default value
0
Display of the signal strength
―
1
Automatic configuration with movement of bulk solids
―
2
Automatic configuration with no movement of bulk
solids
―
3
Manual configuration with movement of bulk solids
―
4
Manual configuration with no movement of bulk solids
―
5
Hysteresis
Summary of Contents for Solimotion FTR20