Installation
FieldPort SWA50
28
Hauser
Installing the mounting bracket on a pipe
‣
Secure the mounting bracket to the pipe at the desired location. Torque: minimum
5 Nm
If you change the position of the support bracket on the mounting bracket, tighten the
four hexagonal-headed bolts with a torque of 4 Nm to 5 Nm.
Installing the mounting bracket on a wall
‣
Secure the support bracket to the wall at the desired location. The screws must be
suitable for the wall.
Mounting the FieldPort SWA50
Follow the instructions in the "Remote mounting version" section → 21.
1. Unscrew the cable glands of the FieldPort SWA50.
2. Unscrew the top housing section.
3. Remove the electronic insert from the housing.
4. Remove the design ring from the bottom housing section.
5. Slide the bottom housing section into the eyelet of the support bracket.
6. Carry out electrical connection for the FieldPort SWA50.
7. Slide the electronic insert into the bottom housing section.
8. Loosely screw on the top housing section.
9. Align the transmission window of the FieldPort SWA50.
10. Tighten the top housing section. Torque: 5 Nm ± 0.05 Nm
11. Connect the protective ground to the hexagonal-headed bolt.
12. Tighten the hexagonal-headed bolt so that the FieldPort SWA50 is secured in the
mounting bracket.
5.6
Post-installation check
Is the device undamaged (visual inspection)?
Does the device comply with the required specifications?
For example:
• Ambient temperature
• Humidity
• Explosion protection
Are the screws that provide strain relief for the electronic insert tightened with the correct
torque?
Is the top housing section tightened with the correct torque?
Are all securing screws, such as those for the optional mounting bracket, firmly tightened?
Are the measuring point identification and labeling correct (visual inspection)?