Specifications
multi EA 5100
176
Computer specifications
Graphics resolution
1280x1024
(1024x768 possible with restrictions)
CD/DVD drive
Interface
Required for software installation
1 USB 2.0
Operating system
Windows 8.1, Windows 10 (32, 64 bit )
Other
Activation of DoNetFrameWork 3.5
17.2 Technical data of the N module 5100
Procedural data
Analytical parameters
Total nitrogen TN
Detection principle
Chemiluminescence
Measuring range (N in sample)
0.01 to 10000 mg/l N
Measuring range (N absolute)
0 to 100 µg N
Electrical variables
Power supply
110 to 240 V +10/-5 %
Overvoltage category
II
Frequency
50/60 Hz
Module fuse protection
Number of device fuses
T 4.0 A H
2
Typical average power consumption
200 VA
Interface to the basic module
RS 232
Only use original fuses from Analytik Jena!
Gas supply
Oxygen 4.5
80 ml/min
400 to 600 kPa (4 to 6 bar)
General characteristics
Dimensions (W x H x D)
300 x 500 x 550 mm
Mass
13 kg
17.3 Technical data for the Cl module 5100
Procedural data
Analytical parameters
AOX, EOX, TX, TCl, TOX, TIX
Detection principle
Micro-coulometric end point titration
(argentometry)
Sample feed
¡
In carrier gas stream (from basic
module)
¡
Direct injection of aqueous samples
and HCl for test purposes
(into the measuring cell)
Temperature control for measuring cell
Integrated cooling