RSTi-OM User Manual
Section 13
GFK-3212A
Jun 2021
Functionality Descriptions
129
Parameter Name
Data Type
Description
Auxiliary I/O
BYTE
The auxiliary bit on the IO-Link port is:
Pin 2 on the IOLM
Bit 0 (0x01): The status of the auxiliary bit.
0 = off
1 = on
Bits 1-3: Reserved (0)
If
Include Digital I/O in PDI Data Block
is disabled:
Bits 4-7: Reserved (0)
Bit 4 (0x10)
–
D1 = DI status Bit 5 (0x20)
–
D2 = DIO status
Bit 6 (0x40)
–
D3 = D2 status Bit 7 (0x80)
–
D4 = DIO status
Event Code
INT
16-bit event code received from the IO-Link device.
PDI Data
Default Length
= 32
bytes
An array of
up to 32
BYTEs
The PDI data was received from the IO-Link device. May
contain from 0 to 32 bytes of PDI data. The definition of
the PDI data is device-dependent.
Note: Length is configurable using the web page interface.
13.1.2
Input Process Data Block-8 Bit Data Format
The following table provides detailed information about the Input Process Data Block-8 Bit data
format.
Byte
Bit 7
Bit 0
0
Port Status
1
Auxiliary I/O
2
Event Code LSB
3
Event Code MSB
4
PDI Data Byte 0
5
PDI Data Byte 1
..
..
..
..
N+3
PDI Data Byte (N-1)