Before you begin
Table 1-3
9739 MVD transmitter configuration settings
continued
Configurable with:
Configuration
parameter
Setting
Display
ProLink II
Field Communi-
cator
API table type:
q
Degrees API, reference
temperature 60
°F
q
Relative Density/Specific
Gravity, reference temperature
60
°F
q
kg/m
3
at user-defined
reference temperature
(Temperature:____)
ü
ü
Petroleum
measurement
application (if
available)
API Units:
q
Generalized Crude or JP4
(API Chapter 11.1 “A” Tables)
q
Generalized Products (API
Chapter 11.1 “B” Tables)
q
User Defined TEC (API
Chapter 11.1 “C” Tables)
ü
ü
Active curve:
ü
ü
Concentration
measurement
application (if
available)
Derived variable:
ü
ü
Weights &
Measures
application (if
available)
Totalizer reset options:
q
Not resettable from display or
digital communications
q
Resettable from digital
communications only
q
Resettable fro display and
digital communications
q
Resettable from display only
ü
Language:
q
English
q
French
q
German
q
Spanish
ü
ü
Transmitter
display
Configuration and Use Manual
7