5.4 EUT Power, supply of the EUT with dc
Caution!
Before a dc supply for the EUT can be used
the two bridges must be removed.
If the bridges are not removed when the EUT
is powered with dc the internal Variac will be
heated and destroyed.
Figure
5.3.6
Preparations:
1. Remove the two bridges on the rear side of the TRA3000 F-S-D-V-C.
2. Connect the DC power supply with EUT - Power 1 d.c inputs. Connect the positive pin of the dc source
with + input and the negative pin with - input.
The TRA3000 can be equipped with different extensions, which results in different operation modes
decribed below:
bridges