11BRemote Ports
128/162
Example: VNOM 4000;POL NEG;Rep 10<EOS>
12.2.3 Inquire Commands
Inquire commands start TRA3000 F-S-D-V-C transmitting internal data to the system controller. The data
consists of two parts:
<Inquire commands>=<head>{< >}<?>
Instead of the argument, a question mark is used in Inquire Commands. A command contains a maximum
of one Inquire Command which must be located at the end of the command. On the other hand several set-
up Commands are allowed:
Examples:
Based on the Inquire Command ...
VNOM ?<EOS>
the following answer can occur:
2000
or: controller:
POL?<EOS>
TRA:
NEG
or: controller:
VNOM 1000;E?<EOS>
TRA:
0
12.2.4 Failure messages remote control:
Error Message
“E?” remote answer
Description
"OK"
"Unknown header"
"Invalid argument"
"Query expected"
"Only on local mode"
"Only on remote mode"
"Only on RUN mode"
"Not in RUN mode"
"Empty"
'0'
':'
'3'
'4'
'l'
'r'
'R'
'N'
'e'
No error.
Unknown command.
Invalid parameter.
No query in message as expected.
Must “GTL” before.
Must “REN” before.
Only when start a test.
Only in standby mode.
No argument in message as expected.
Summary of Contents for EXTTRA3000 E
Page 8: ...TRANSIENT3000 8 162...
Page 102: ...TRANSIENT3000 102 162...
Page 106: ...TRANSIENT3000 106 162...
Page 116: ...TRANSIENT 2000 116 162...
Page 118: ...TRANSIENT 2000 118 162...
Page 142: ...11BRemote Ports 142 162 All Generators of EMCP can be loaded and demonstrated...
Page 148: ...12BAppendix and Corrections 148 162 13 1 6 VARIATION Specification IEC 61000 4 11 Ed 2...
Page 150: ...12BAppendix and Corrections 150 162...
Page 156: ...14BIndex 156 162...
Page 158: ...14BIndex 158 162...
Page 160: ...14BIndex 160 162...
Page 162: ...14BIndex 162 162...