13 Serial Remote Control
13.1 General
The MIG remote-control-option enables remote control of the MIG via the RS-232 serial port.
.
13.1.1 Technical Data of the RS 232C serial port
The V.24 serial port uses the data lines TxD and RxD for the information transfer.
Baudrate:
1200, 2400, 4800, 9600,
19200
Databits:
7,
8
Parity:
None
, Even, Odd
Stop:
1
, 2
Protocol:
None
, RTS/CTS, XON/XOFF
End of sequence:
CR
, LF, CR+LF
With the pinning below the remote control of a TRA2000 or MIG2000 generator is guaranteed.
Pinning
Signal
9 pol SubD
Signal
25 pol SubD
TxD
Pin 3
TxD
Pin 2
RxD
Pin 2
RxD
Pin 3
RTS
Pin 7
RTS
Pin 4
CTS
Pin 8
CTS
Pin 5
DCD
Pin 1
DCD
Pin 8
DSR
Pin 6
DSR
Pin 6
DTR
Pin 4
DTR
Pin 20
GND
Pin 5
GND
Pin 7
RI
Pin 9
RI
Pin 22
Standard Nullmodem
TxD
3
>>>>>>>
RxD
3
RxD
2
>>>>>>>
TxD
2
RTS + CTS
7 + 8
>>>>>>>
DCD
8
DCD
1
>>>>>>>
RTS + CTS
4 + 5
DSR + DTR
6 + 4
>>>>>>>
DSR + DTR
6 + 20
GND
5
>>>>>>>
GND
7
3-Wire Nullmodem
TxD
3
>>>>>>>
RxD
3
RxD
2
>>>>>>>
TxD
2
RTS+CTS+DCD
7 + 8 + 1
RTS+CTS+DCD
4 + 5 + 8
DSR + DTR
6 + 4
DSR + DTR
6 + 20
GND
5
>>>>>>>
GND
7
EMCP 25/9 pole cable
TxD
3
>>>>>>>
RxD
3
RxD
2
>>>>>>>
TxD
2
RTS
7
>>>>>>>
DCD
8
CTS + DSR
8 + 6
>>>>>>>
DTR
20
DCD
1
>>>>>>>
RTS
4
DTR
4
>>>>>>>
CTS + DSR
5 + 6
GND
5
>>>>>>>
GND
7
Min. wiring for remote
TxD
3
>>>>>>>
RxD
3
control cable
RxD
2
>>>>>>>
TxD
2
RTS + CTS
7 + 8
GND
5
>>>>>>>
GND
7
Change Communication Parameters:
To change the communication values on the generator go to the REM (Remote) menu:
after power-on push
Æ
MAIN
Æ
MENU
Æ
MENU
Æ
REM. There you can change the values.
Recommended parameters are:
19200 Baud, CR, no protocol, 8 databit, 1 stopbit, no parity
Summary of Contents for 103514
Page 7: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 7 112...
Page 22: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 22 112...
Page 25: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 25 112 1 7 2 Standard accessories...
Page 26: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 26 112...
Page 38: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 38 112...
Page 60: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 60 112...
Page 68: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 68 112...
Page 70: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 70 112...
Page 72: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 72 112...
Page 74: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 74 112...
Page 96: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 96 112...
Page 100: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 100 112...
Page 106: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 106 112...
Page 108: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 108 112...
Page 110: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 110 112...
Page 112: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 112 112...