Dual Surge Tester K12
Application:
SURGE peak current test on Two electrode
gaze arrestor
Waveforms:
i = 8/20, 10/700, 10/350 µs
Range:
2 x i = 6’000, 120, 240 A
1 x i = 10’000, 240, 480 A
Standard: UIT
K12
The „MIG0603K12 is a dual output surge current generator for testing protective elements like arresters, or
Transzorbe diodes with different waveforms.
The dual output allows testing of three electrode elements .The current ranges are: for 8/20 µs up to
2x6'000 A, for 10/700 µs up to 2x120 A and for 10/350 µs up to 2x240 A.
For two electrode elements the outputs of the generator can be connected in parallel, to increase the
current capability up to 240 A for 10/700 µs, 480 A for 10/350 µs and 12 kA for 8/20 µs.
The charging voltage up to 6300 V is sufficient for most of the protection elements, also for elements with
relatively high clamping voltages.
The peak output voltage and current of the MIG are indicated on the front display. The two BNC monitor
outputs (v,i) allow monitoring the voltage and current wave shapes by an oscilloscope connected onto.
1.3.4
MIG for X,Y, capacitor tests
, CWG
1,2/50 µs Capacitor Tester
Application:
Insulation test on X, Y capacitors
Waveforms:
1,2/50 µs voltage
Resistor:
3, 5, 7, 9, 13, 25, 27, 45, 62
Range:
0 up to 2 µF
Standard: IEC
60348-14
Flammability Tester
Application:
flammability test on X, Y capacitors
Range:
capacitors up to 4 µF Vmax 6000V
capacitor up to 10 µF Vmax 4000V
Standard: IEC 60348-14 Amd. 1
1.3.5
Combination wave tester
CWG
Different Surges
Application:
Household equipment, Telecommunication
equipment
Waveforms:
1,2/50 µs, 8/20 µs CWG
Options:
Ring wave 0.5 µs, 100 kHz
10/700 µs
Range:
0.25 to 6.6 kV
Coupling: for single phase included
Standards: IEC 61000-4-5,
IEC 61000-4-12, UIT K17
MIG0603IN
The MIG0603-IN can include up to three different waveforms like: CWG (1,2/50; 8/20 ); CCITT (10/700,
0,5/700) or ANSI, IEC 61000-4-12 ring wave 0,5/100kHz.
The MIG0603IN is a surge generator for simulation of indirect lightning on telecom and process and
measurement lines. The relevant recommendations are CCITT K17 and IEC 61000-4-5.
The MIG0603IN is a hybrid generator with a voltage waveshape 1,2/50 µs at "no load" and a current wave-
form 8/20 µs at short circuit.
At 2 Ohm source impedance of the MIG0603IN, the voltage and current waveform can be guaranteed at
the terminal of a 1 m connection cable. Instead of the cable connection a test cabinet can be placed on the
top of the generator. The test cabinet is so designed that the cover can not be opened during the test. The
green and red warning lamps are integrated in the test cabinet.
The peak output voltage and current of the MIG are indicated on the display. The two BNC monitor outputs
allow monitoring the voltage and current wave shapes by an oscilloscope
Summary of Contents for 103514
Page 7: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 7 112...
Page 22: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 22 112...
Page 25: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 25 112 1 7 2 Standard accessories...
Page 26: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 26 112...
Page 38: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 38 112...
Page 60: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 60 112...
Page 68: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 68 112...
Page 70: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 70 112...
Page 72: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 72 112...
Page 74: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 74 112...
Page 96: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 96 112...
Page 100: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 100 112...
Page 106: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 106 112...
Page 108: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 108 112...
Page 110: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 110 112...
Page 112: ...MIG OS OS1_MIG0603OS1_MIG0603OSI Modular Impulse Generator 112 112...