_________________________________________________________________________________
_________________________________________________________________________________
26
Universal Network Terminal TAU-32M.IP
2.7
'F' Function Button Operation
To reboot the operating device, press and hold 'F' button located on the front panel of the device for 1 to 9
seconds. When releasing the button, the
Alarm
LED will become solid red and the device will reboot. Also, this
button allows you to reset the device to factory settings to get access to the device when the IP address or the
password is forgotten or is not known. To do this, press and hold the 'F' button for 10-14 seconds until the
Status
LED begins to flash yellow, green and red alternatively. Then the
Alarm
LED becomes solid red and the button
should be released. The configuration will be reset to factory settings and the device will be rebooted. After that,
you can access the device by IP address
192.168.1.2.
When connecting with Web configurator, the default password
for
admin
user is
rootpasswd.
Further, you can view/change IP address and set a new password. If the button is not
released during the period between 10 and 14 seconds, after a while all LEDs will go out (the device will start
rebooting). Soon after the
Status
LED will begin to flash yellow, green and red alternatively, and the
Alarm
LED will
begin to flash red. When releasing the 'F' button at this moment, the configuration will not be reset to factory
settings and will switch to the
Safemode
. This mode allows changing the factory configuration, in other words,
selecting a method of network settings obtaining - statically or dynamically. If you continue to hold the ‘F’ button in
the
Safemode
, the cycle of the button operation will be repeated, that is, the restart will occur again if the button is
held for 1 to 9 seconds, the reset to the factory settings if the button is held for 10 to 14 seconds, etc.
For detailed description of the factory reset procedure, see Section 6.5 Reset the device to the factory
2.8
Delivery Package
TAU-32M.IP standard delivery package includes:
–
Universal Network Terminal TAU-32M.IP;
–
CENC-36M connector - 2 pcs. (if there is no UTP CAT5E 18 cable in the order);
–
Power cable (if equipped with 220V power supply);
–
PVS cable (if equipped with 48V power supply);
–
RS-232 DB9(F) – DB9(F) cable for console port connection.
–
Grounding cable (if equipped with 48V power supply);
–
A mounting set for 19" rack;
–
User manual;
–
Declaration of conformity.
If ordered, delivery package may also include:
–
1000Base-T/Mini-Gbic (SFP) optical interface – 2pcs;
–
UTP CAT5E 18 cable with CENC-36M connectors - 1 pcs.