![Electrolux 30](http://html.mh-extra.com/html/electrolux/30-gas-freestanding-ranges/30-gas-freestanding-ranges_service-manual_91284030.webp)
30
Figure 8
B. Surface Burner Valves Conversion
Top Burner Adjustment
Figure 9
1. Lift cooktop to gain access to the surface
burner spuds.
2. With ½” wrench, turn spud down or clockwise
until snug (approximately 2 ½ turns). This re-
stricts the flow of gas through spud to that al-
lowed only by the hollow LP metering pin.
Do
not overtighten.
Figure 10
3.Lower main top and apply gas to check for proper flame
size. Flame should be steady with approximately ½”
blue inner cones and no yellow or orange tips.
Figure 11
Proper Air Adjustment
If air shutter is adjusted so that too much air flows
into the burner, the flame will appear unsteady,
possibly not burning all the way around and will be
noisy (like a blow torch).
C. Readjust the “LOW” Setting Surface Burner
Valve
1. Turn control to LITE until burner ignites.
2. Quickly turn knob down to LOWEST SETTING.
3. If burner goes out, readjust valve as described
in “Adjust the LOW Setting Surface Burner
Valve” from Page .
D. Air Adjustment Shutter
Apply gas to the burner and adjust air shutter on
burner venturi tube to proper flame. For LP gas,
the air shutter is generally left completely open.
Figure 12
The air adjustment for each burner is located at
the open end of the venturi tube and sits on the
hood of the valve. The shutter is held in place by
friction fit.
Air Shutter
Pin
Nat.
Hood
L.P.
Spud
Natural Gas
Increase Gas
Increase Flame
Size
(Pre-Set at Factory
for Natural Gas)
L.P. Gas
Decrease Gas
Decrease Flame
Size
Pin
½"
Inner Cone Flame Length
Air adjustment shutter
NAT.
L.P.
Cap Screw
Summary of Contents for 30" GAS FREESTANDING RANGES
Page 43: ...43 SAMPLE SCHEMATIC FOR ES100 CONTROL SYSTEM ...
Page 50: ...50 SAMPLE SCHEMATIC FOR ES 200 CONTROL SYSTEM ...
Page 60: ...60 SAMPLE SCHEMATIC FOR ES 300 CONTROL SYSTEM ...
Page 72: ...72 SAMPLE SCHEMATIC FOR ES 400 CONTROL SYSTEM ...
Page 84: ...84 SAMPLE SCHEMATIC FOR ES 450 CONTROL SYSTEM ...
Page 93: ...93 Sample schematic for 36 gas range ...
Page 130: ...130 NOTES ...
Page 131: ...131 NOTES ...
Page 132: ...132 ...