![Ecolab Elados EMP KKS E60 Operating Instructions Manual Download Page 260](http://html.mh-extra.com/html/ecolab/elados-emp-kks-e60/elados-emp-kks-e60_operating-instructions-manual_2354530260.webp)
14.4
Materials
Pump head:
PVDF
Metering-piston/-cylinder:
Ceramic
Diaphragms:
PTFE-EPDM composite
Seals:
FPM (Viton B), optionally EPDM
Valves:
PVDF
Valve-balls:
Ceramics
O-ring:
FPM, optionally EPDM
Valve-springs:
Hastelloy C4/C22 PTFE coated
Housing:
thermoplastic polyester
Colour:
blue, RAL 5007
Special versions available on request.
14.5
In-/ and output circuit
14.5.1 Connector I
Fig. 91: Connector I
input
allocation
external circuit
empty report
1 (brown)
+
4 (black)
voltage-free contact
Note: do not connect any external voltages!
reserve
3 (blue)
+
4 (black)
Technical Specifications
124
417101442 Rev. 12-02.2019
Summary of Contents for Elados EMP KKS E60
Page 2: ......
Page 123: ...14 2 Abmessungen Abb 89 Abmessungen Technische Daten 121 417101442 Rev 12 02 2019 ...
Page 135: ......
Page 258: ...14 2 Dimensions Fig 90 Dimensions Technical Specifications 122 417101442 Rev 12 02 2019 ...
Page 393: ...14 2 Dimensions Fig 93 Dimensions Données techniques 123 417101442 Rev 12 02 2019 ...
Page 405: ......