10.2.3.2 Display in the operating display/ Setting
Display in the operating display/ Setting:
Multiplication
Display in the operating display/ Setting:
Division
The multiplication and division factors are configured / adjusted in the operating display.
This can take place while the pump is operating.
NOTICE!
If the newly set value is not confirmed within 10 seconds by pressing the
START/STOP key, the system reverts to the previously set running value.
10.2.4 Operation mode / current (external standard signal)
In the “current” operation mode, the pump functions on the basis of an incoming standard
signal.
The incoming signal (0/4-20 mA; 20-0/4 mA or adjustable) is converted into a metering
frequency 0-100 % (stroke/pause ratio), e.g.:
Folgende Betriebsvarianten stehen zur Auswahl:
0 – 20 mA:
0 mA = 0 % metering frequency, 20 mA = 100 % metering frequencyz
4 – 20 mA:
4 mA = 0 % metering frequency, 20 mA = 100 % metering frequency
20 – 0 mA:
20 mA = 0% metering frequency, 0 mA = 100 % metering frequency
20 – 4 mA:
20 mA = 0% metering frequency, 4 mA = 100 % metering frequency
User defined
n (adjustable) mA = 0 % metering frequency,
n (adjustable) mA = 100 % metering frequency
Menu description
68
417101442 Rev. 12-02.2019
Summary of Contents for Elados EMP KKS E60
Page 2: ......
Page 123: ...14 2 Abmessungen Abb 89 Abmessungen Technische Daten 121 417101442 Rev 12 02 2019 ...
Page 135: ......
Page 258: ...14 2 Dimensions Fig 90 Dimensions Technical Specifications 122 417101442 Rev 12 02 2019 ...
Page 393: ...14 2 Dimensions Fig 93 Dimensions Données techniques 123 417101442 Rev 12 02 2019 ...
Page 405: ......